![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1014837.1 : Tape - How to Test for Configuration Problems that Can Cause 3E24 Errors
PreviouslyPublishedAs 222245 Applies to:Sun Storage SDLT 600 Tape Drive - Version Not Applicable and laterSun StorageTek T10000 Tape Drive - Version Not Applicable and later Sun StorageTek 9840 Tape Drive - Version Not Applicable and later LTO Tape Drive - Version Not Applicable and later Sun StorageTek 9940B Tape Drive - Version Not Applicable and later All Platforms SymptomsThe 3E24 error is from the library being told to move a tape from the drive when the drive is loaded and ready and not showing any signs over the TTI that it is unloading. CauseThis error is usually only seen for one of two reasons: SolutionA simple test for a configuration error is to be sure a mount and dismount of each drive, ONE drive at a time, works and that the drive gets unloaded from the host properly. 1. If there is a mismatch in the configuration, the drive will not come ready to the host because the host is really waiting for an empty drive to come ready. This is not so easy to detect when all drives are loaded and backups running! Attachments This solution has no attachment |
||||||||||||
|