![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1013433.1 : SL8500 - Unable to Communicate on the Network When its IP address is Modified or a New Address is Assigned.
PreviouslyPublishedAs 218800 Applies to:Sun StorageTek SL8500 Modular Library System - Version Not Applicable and laterAll Platforms SymptomsNo communication over the network Changes{CHANGE} CauseAdditional Information The switch rebuilds the address table each time an IP address is modified or a new IP address is created. Although this condition was experienced on a Cisco Calalyst 5000 switch, it may apply to other brand of switches. Check with customer network engineers to determine the number of switches or other network appliances that may be affected. Solution