Solution Type Problem Resolution Sure Solution 1012604.1 : Sun Fire[TM] E2900/V1280: mpt driver fails to attach to PCI-X Dual Ultra-320 SCSI HBA (Jasper320)
PreviouslyPublishedAs 217346 Applies to:Sun Fire V1280 Server - Version Not Applicable and laterSun Fire E2900 Server - Version Not Applicable and later All Platforms SymptomsWith firmware revision 5.19.0-4 and also 5.18.3, if POST is run with "diag-level" set to "max" in OBP and/or "bootmode" is set to "diag" in "lom" with a Jasper320 HBA (pn# 375-3191) installed in the system, the HBA would not get recognised in OBP, thus failing to load the "mpt" driver during Solaris bootup. CauseThe described configuration Solution
Sep 14 10:18:20 ct41-c1-1 mpt: [ID 576234 kern.warning] WARNING: ID[SUNWpd.mpt.attach.4011] Sep 14 10:18:25 ct41-c1-1 genunix: [ID 408789 kern.warning] WARNING: mpt3: fault detected in device; service unavailable Sep 14 10:18:25 ct41-c1-1 genunix: [ID 451854 kern.warning] WARNING: mpt3: firmware load failed Sep 14 10:18:25 ct41-c1-1 genunix: [ID 408822 kern.info] mpt3: fault detected in device; service still unavailable Sep 14 10:18:25 ct41-c1-1 genunix: [ID 611667 kern.info] mpt3: hard reset failed Sep 14 10:18:25 ct41-c1-1 genunix: [ID 408822 kern.info] mpt3: fault detected in device; service still unavailable Sep 14 10:18:25 ct41-c1-1 genunix: [ID 611667 kern.info] mpt3: mpt ioc initialization failed Sep 14 10:18:25 ct41-c1-1 0x09attach failed Sep 14 10:18:25 ct41-c1-1 mpt: [ID 576234 kern.warning] WARNING: ID[SUNWpd.mpt.attach.4011] Sep 14 10:19:19 ct41-c1-1 genunix: [ID 408822 kern.info] mpt2: fault detected in device; service still unavailable Sep 14 10:19:19 ct41-c1-1 genunix: [ID 611667 kern.info] mpt2: firmware load failed Sep 14 10:19:19 ct41-c1-1 genunix: [ID 408822 kern.info] mpt2: fault detected in device; service still unavailable Sep 14 10:19:19 ct41-c1-1 genunix: [ID 611667 kern.info] mpt2: hard reset failed Sep 14 10:19:19 ct41-c1-1 genunix: [ID 408822 kern.info] mpt2: fault detected in device; service still unavailable Sep 14 10:19:19 ct41-c1-1 genunix: [ID 611667 kern.info] mpt2: mpt ioc initialization failed Sep 14 10:19:19 ct41-c1-1 0x09attach failed Sep 14 10:19:19 ct41-c1-1 mpt: [ID 576234 kern.warning] WARNING: ID[SUNWpd.mpt.attach.4011] Sep 14 10:19:59 ct41-c1-1 genunix: [ID 408822 kern.info] mpt3: fault detected in device; service still unavailable Sep 14 10:19:59 ct41-c1-1 genunix: [ID 611667 kern.info] mpt3: firmware load failed Sep 14 10:19:59 ct41-c1-1 genunix: [ID 408822 kern.info] mpt3: fault detected in device; service still unavailable Sep 14 10:19:59 ct41-c1-1 genunix: [ID 611667 kern.info] mpt3: hard reset failed Sep 14 10:19:59 ct41-c1-1 genunix: [ID 408822 kern.info] mpt3: fault detected in device; service still unavailable Sep 14 10:19:59 ct41-c1-1 genunix: [ID 611667 kern.info] mpt3: mpt ioc initialization failed Sep 14 10:19:59 ct41-c1-1 0x09attach failed When probe-scsi-all is run at the ok prompt, following messages are seen : {0} ok probe-scsi-all /ssm@0,0/pci@19,700000/scsi@3,1 <-----Failed ERROR: LSI1030: Reset Error. IOC State Not Ready. Can't open SCSI host adapter /ssm@0,0/pci@19,700000/scsi@3 ERROR: LSI1030: Reset Error. IOC State Not Ready. Can't open SCSI host adapter To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in an appropriate My Oracle Support Community, Oracle Sun Technologies Community.
The fix is available in 5.19.5 and 5.20.0. Additional details are documented in the bug for recovering this failure at the "ok" prompt using OBP/Forth commands
jasper320, jasper, lw8, mpt, LSI1030, Reset, probe-scsi-all, e2900, v1280 Attachments This solution has no attachment |
||||||||||||
|