Solution Type Problem Resolution Sure Solution 1010536.1 : Sun Fire[TM] V1280, E2900, Netra[TM] 1280, and 1290 Servers: Programming LOM Failed with Error: Resource Temporarily Unavailable
PreviouslyPublishedAs 214485 Applies to:Sun Fire V1280 Server - Version Not Applicable and laterSun Netra 1280 Server - Version Not Applicable and later Sun Fire E2900 Server - Version Not Applicable and later All Platforms SymptomsWhen updating the firmware, flashupdate or lom -G may error with: Programming LOM(Lights Out Management) failed with error: Resource temporarily unavailable CauseSee solution
Solution
Example situation: This example was from a Sun Fire[TM] v1280 system where the update failed during the update of the cpu/mem boards: # lom -G lw8cpu.flash This program will replace LOM firmware with version 5.17.0 Are you sure you want to continue? Enter 'C' and return to Continue or anything else to Terminate C Programming LOM(Lights Out Management) failed with error: Resource temporarily unavailable
lom> resetsc -y 1. Upgrade the firmware on the SC: # lom -G sgsc.flash # lom -G sgrtos.flash 2. Escape to lom> by entering the following: # . 3. Reset the SC: lom>resetsc -y 4. After you reset the SC, proceed with upgrading the boards in the system: # lom -G lw8cpu.flash # lom -G lw8pci.flash 5. Escape to lom> again, shutdown the system, and then power everything on again. lom>shutdown lom>poweron (Note: The shutdown command shuts down the Solaris[TM] Operating System, so make sure the server is ready to be unavailable for the duration of the shutdown and poweron steps)
To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in an appropriate My Oracle Support Community, Oracle Sun Technologies Community.
v1280, 2900, 1280, 1290, firmware, lom, Resource Temporarily Unavailable, Programming LOM Failed, Error, lom -g, flashupdate, resetsc, scapp, normalized Attachments This solution has no attachment |
||||||||||||
|