Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1009829.1
Update Date:2017-02-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  1009829.1 :   Sun Fire[TM] T2000 Hangs during Boot.  


Related Items
  • Sun Fire T2000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: Tx000
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>CMT Servers
  •  

PreviouslyPublishedAs
213486


Applies to:

Sun Fire T2000 Server - Version Not Applicable to Not Applicable [Release N/A]
All Platforms

Symptoms

When booting or rebooting a Sun Fire[TM] T2000 the boot process hangs at "checking ufs volumes" but before "/dev/... logging" messages. Machine was fine until modem was attached to the serial port (ttya). Machine is running Solaris[TM]10 11/06.

Cause

T2000 is running Solaris[TM]10 11/06.

Solution

Resolution
The following should help address:
Problem only appears with those T2000's running Solaris[TM]10 11/06 (S10_u3).
Installing Patch ID :120011-14 or later will fix the problem.

Relief/Workaround
Remove modem or serial device from serial port prior to booting/rebootin then re-attach after machine has fully booted.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.