Solution Type Problem Resolution Sure Solution 1009614.1 : Sun StorEdge[TM] 351x: Shows some FRU as absent
PreviouslyPublishedAs 213243 Applies to:Sun Storage 3510 FC Array - Version Not Applicable and laterSun Storage 3511 SATA Array - Version Not Applicable and later All Platforms SymptomsAn array will have the LEDS showing as healthy but the "sccli" command "show fru" may show parts as absent and "sccli" command "show ses" will not show all the SES devices: sccli> show ses
Ch Id Chassis Vendor/Product ID Rev PLD WWNN WWPN ------------------------------------------------------------------------------- 3 28 00662C SUN StorEdge 3511F A 0413 1000 2040xxxxxxxxxxxx 2240xxxxxxxxxxxx sccli> show frus 7 FRUs found in chassis SN#00XXXX at ch 3 id 28 Name: FC_CHASSIS_BKPLN Description: SATA,Chassis+Backplane, 2U Part Number: XXX-XXXX Serial Number: XXXXXX Revision: 01 Manufacturing Date: Sun May 23 01:42:09 2004 Manufacturing Location: Milpitas,CA,USA Manufacturer JEDEC ID: 0x0123 FRU Location: FC MIDPLANE SLOT Chassis Serial Number: XXXXXX FRU Status: OK Name: FC_RAID_IOM Description: N/A Part Number: N/A Serial Number: N/A Revision: N/A Manufacturing Date: N/A Manufacturing Location: N/A Manufacturer JEDEC ID: N/A FRU Location: UPPER FC RAID IOM SLOT Chassis Serial Number: XXXXXX FRU Status: Absent Name: BATTERY_BOARD Description: N/A Part Number: N/A Serial Number: N/A Revision: N/A Manufacturing Date: N/A Manufacturing Location: N/A Manufacturer JEDEC ID: N/A FRU Location: UPPER BATTERY BOARD SLOT Chassis Serial Number: XXXXXX FRU Status: Absent Name: AC_POWER_SUPPLY Description: AC PWR SPLY FAN MOD 2U FC/SATA Part Number: XXX-XXXX Serial Number: XXXXXX Revision: 01 Manufacturing Date: Sat Aug 28 13:16:17 2004 Manufacturing Location: Irvine California, USA Manufacturer JEDEC ID: 0x0123 FRU Location: RIGHT AC PSU SLOT #1 (RIGHT) Chassis Serial Number: XXXXXX FRU Status: OK Name: AC_POWER_SUPPLY Description: AC PWR SPLY FAN MOD 2U FC/SATA Part Number: XXX-XXXX Serial Number: XXXXXX Revision: 01 Manufacturing Date: Sun Dec 26 05:48:15 2004 Manufacturing Location: Irvine California, USA Manufacturer JEDEC ID: 0x0123 FRU Location: AC PSU SLOT #0 (LEFT) Chassis Serial Number: XXXXXX FRU Status: OK Name: FC_RAID_IOM Description: SE3511 I/O w/SES RAID SATA 2U Part Number: XXX-XXXX Serial Number: XXXXXX Revision: 03 Manufacturing Date: Wed Mar 16 22:19:34 2005 Manufacturing Location: Milpitas California, USA Manufacturer JEDEC ID: 0x0123 FRU Location: LOWER FC RAID IOM SLOT Chassis Serial Number: XXXXXX FRU Status: Fault Name: BATTERY_BOARD Description: BATTERY 2U, FC/SATA Part Number: XXX-XXXX Serial Number: XXXXXX Revision: 01 Manufacturing Date: Sun Jun 13 19:10:31 2004 Manufacturing Location: Milpitas,CA,USA Manufacturer JEDEC ID: 0x0123 FRU Location: LOWER BATTERY BOARD SLOT Chassis Serial Number: XXXXXX FRU Status: OK
CauseThis could happen if PID and/or SID of Drive Channels are changed from default.
There are other potential causes of this issue (with similar symptoms), which can include faulty controllers, other component failures, incorrectly seated components. Refer to the Reference section below. Solution
References<NOTE:1004958.1> - StorEdge[TM] 3510FC Array Controller LED Amber,"show fru" Missing FRUsAttachments This solution has no attachment |
||||||||||||
|