![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1009343.1 : SUNWjfca HBA will not have any bug fixes
PreviouslyPublishedAs 212925 Applies to:Sun Storage 3310 Array - Version Not Applicable and laterSun Storage 3320 SCSI Array - Version Not Applicable and later Sun Storage 3510 FC Array - Version Not Applicable and later Sun Storage 3511 SATA Array - Version Not Applicable and later Sun Storage 6130 Array - Version Not Applicable and later All Platforms SymptomsWhen a customer connects a SunStorEdge[TM] array to SUNWjfca hba, they may meet known bugs which will not be corrected by the provider AMCC . ChangesN/A CauseKnown bugs which will not be corrected by the provider AMCC . SolutionSun Bug: 6255879 Apr 7 11:59:27 nas0003 jfca: [ID 276417 kern.info] jfca1: Link Down Apr 7 11:59:27 nas0003 jfca: [ID 277441 kern.info] jfca3: Link Down Apr 7 11:59:27 nas0003 scsi: [ID 107833 kern.warning] WARNING:/scsi_vhci/ssd@g600c0ff00000000007ff4e1c7dd48b00 (ssd24): Apr 7 11:59:27 nas0003 SCSI transport failed: reason 'tran_err': retrying command Apr 7 11:59:28 nas0003 jfca: [ID 551955 kern.info] jfca1: Auto-Configured as Private Loop port Apr 7 11:59:29 nas0003 jfca: [ID 359586 kern.info] jfca1: Link Up: 2Gig Loop Apr 7 11:59:29 nas0003 fctl: [ID 999315 kern.warning] WARNING: fctl(1): AL_PA=0x2 doesn't exist in LILP map Apr 7 11:59:38 nas0003 jfca: [ID 780306 kern.info] jfca3: Link Failure event detected Apr 7 11:59:40 nas0003 jfca: [ID 302589 kern.info] jfca3: Auto-negotiating link speed Apr 7 11:59:40 nas0003 jfca: [ID 556780 kern.info] jfca3: Topology configuration is set to Auto-Negotiate Apr 7 11:59:55 nas0003 jfca: [ID 302589 kern.info] jfca3: Auto-negotiating link speed Apr 7 11:59:55 nas0003 jfca: [ID 556780 kern.info] jfca3: Topology configuration is set to Auto-Negotiate Apr 7 11:59:57 nas0003 jfca: [ID 276417 kern.info] jfca1: Link Down Apr 7 11:59:57 nas0003 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g600c0ff00000000007ff4e1c7dd48b01 (ssd23): Apr 7 11:59:57 nas0003 SCSI transport failed: reason 'tran_err': retrying command Apr 7 11:59:57 nas0003 jfca: [ID 551963 kern.info] jfca3: Auto-Configured as Private Loop port Apr 7 11:59:57 nas0003 jfca: [ID 551955 kern.info] jfca1: Auto-Configured as Private Loop port Apr 7 11:59:58 nas0003 jfca: [ID 551963 kern.info] jfca3: Auto-Configured as Private Loop port Apr 7 11:59:58 nas0003 last message repeated 1 time Apr 7 11:59:58 nas0003 jfca: [ID 359586 kern.info] jfca1: Link Up: 2Gig Loop Apr 7 11:59:59 nas0003 jfca: [ID 841822 kern.info] jfca3: Link Up: 2Gig Loop Apr 7 12:00:31 nas0003 jfca: [ID 276417 kern.info] jfca1: Link Down Apr 7 12:00:31 nas0003 jfca: [ID 277441 kern.info] jfca3: Link Down Apr 7 12:00:32 nas0003 jfca: [ID 551955 kern.info] jfca1: Auto-Configured as Private Loop port Apr 7 12:00:32 nas0003 jfca: [ID 551963 kern.info] jfca3: Auto-Configured as Private Loop port Apr 7 12:00:33 nas0003 jfca: [ID 359586 kern.info] jfca1: Link Up: 2Gig Loop Apr 7 12:00:33 nas0003 jfca: [ID 841822 kern.info] jfca3: Link Up: 2Gig Loop Apr 7 12:00:33 nas0003 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g600c0ff00000000007ff4e1c7dd48b01 (ssd23): Apr 7 12:00:33 nas0003 Error for Command: write(10) Error Level: Retryable Apr 7 12:00:33 nas0003 scsi: [ID 107833 kern.notice] Requested Block: 40384 Error Block: 40384 Apr 7 12:00:33 nas0003 scsi: [ID 107833 kern.notice] Vendor: SUN Serial Number: 1C7DD48B-01 Sun Bug: 6329781 Sep 22 10:11:05 pythie1 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g600a0b800018928e0000327342c4bfe5 (ssd11):----$modifiedBy---- Sep 22 10:11:05 pythie1 SCSI transport failed: reason 'tran_err': retrying command----$modifiedBy---- Sep 22 10:19:58 pythie1 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g600a0b800018928e0000327242c4bd69 (ssd9):----$modifiedBy---- Sep 22 10:19:58 pythie1 SCSI transport failed: reason 'tran_err': retrying command----$modifiedBy---- Sep 22 10:20:58 pythie1 scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci (scsi_vhci0):----$modifiedBy---- Sep 22 10:20:58 pythie1 /scsi_vhci/ssd@g600a0b800018928e0000327242c4bd69 (ssd9): Command Timeout on path /pci@1e,600000/SUNW,jfca@3/fp@0,0 (fp1)----$modifiedBy---- Sep 22 10:20:58 pythie1 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g600a0b800018928e0000327242c4bd69 (ssd9):----$modifiedBy---- Sep 22 10:20:58 pythie1 SCSI transport failed: reason 'timeout': retrying command----$modifiedBy---- Sep 22 10:21:34 pythie1 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g600a0b800018928e0000327242c4bd69 ...... After basic troubleshooting included SFK patches upgrade, the only way to recover the issue is to replace the faulty HBA by SUNWqlgc. .
Attachments This solution has no attachment |
||||||||||||
|