Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1008351.1
Update Date:2012-07-30
Keywords:

Solution Type  Problem Resolution Sure

Solution  1008351.1 :   Brocade Silkworm[TM] Switch portPhys State "Mod_Val"  


Related Items
  • Brocade 200E Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Switch>SN-DK: Brocade Switch
  •  
  • _Old GCS Categories>Sun Microsystems>Switches>Brocade
  •  

PreviouslyPublishedAs
211422


Symptoms
Some ports in a Brocade Silkworm[TM] 200/E Switch showed portPhys State as "Mod_Val".
Fabric OS:  v5.0.1a
:
:
switchshow:
switchName: swd77
switchType: 34.0
switchState: Online
:
:
Area Port Media Speed State
==============================
0 0 id N4 Online F-Port 21:00:00:e0:8b:91:c7:bf
1 1 id N4 Online F-Port 21:00:00:e0:8b:88:9e:80
2 2 id N4 Laser_Flt
3 3 id N4 Online F-Port 21:00:00:e0:8b:87:9c:bf
4 4 id N2 Online F-Port 20:04:00:a0:b8:21:11:5c
5 5 id N4 Mod_Val <----------------???
6 6 id N4 Mod_Val <----------------???
7 7 id N4 Mod_Val <----------------???
8 8 -- N4 No_Module (No POD License) Disabled
:
:
swd77:admin> portshow 7
portName:
portHealth: No License
Authentication: None
portDisableReason: None
portCFlags: 0x1
portFlags: 0x4001 PRESENT U_PORT LED
portType: 11.0
portState: 2 Offline
portPhys: 10 Mod_Val <--------------------------????
portScn: 0
port generation number: 0
portId: 010700
portIfId: 43020007
portWwn: 20:07:00:05:1e:02:c9:dc
portWwn of device(s) connected:
None
Distance: normal
portSpeed: N4Gbps


Resolution
"Mod_Val" is not documented to be a valid state in either the Fabric OS online help or Brocade hardware documentations. It was however, mentioned in some Fabric OS release notes where bugs in the firmware left a port in the "Mod_Val" state. Therefore we could assumed that "Mod_Val" is supposed to be an internal port state that was not meant to be presented to the end-user, but occurs when a certain error condition is met.

For troubleshooting purposes, a port state of "Mod_Val" can be indicative of a fault state, but the cause may be hardware or firmware, therefore, normal hardware fault isolation must be performed to rule out component failures.

In the specific case above, the cause was determined to be faulty SFP in all 3 ports (5, 6 and 7) showing "Mod_Val". Replacing all 3 SFP's resolved the problem.

In cases listed in Fabric OS release notes where "Mod_Val" state occurs due to firmware issues, disable/enable the port may resolve the problem.



Additional Information
For further details see:

Case: 10951144
Task: 22030415



Product
Brocade 200E Switch

brocade, silkworm, sw200e, Mod_Val, portPhys
Previously Published As
88124

Change History
Date: 2006-12-24
User Name: 31620
Action: Approved
Comment: Verified Metadata - ok
Verified Keywords - ok
Verified still correct for audience - currently set to contract
Audience left at contract as per FvF at
http://kmo.central/howto/content/voyager-contributor-standards.html
Checked review date - currently set to 2007-12-23

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback