Symptoms
The Secure Application Switch log fills with messages like this:
ID	Date	           Level Subsystem	Message
10271 	9/7/2006-08:41:00 warning IP 	101a9: ICMP echo reply failed - IP unable to send to 10.1.50.4
10269 	9/7/2006-08:40:55 warning IP 	101a9: Last message repeated 4 times
10268 	9/7/2006-08:40:55 warning IP 	101a9: ICMP echo reply failed - IP unable to send to 10.1.50.4


Resolution
The problem is usually caused by some application that is sending
ICMP echo request such as IPMP probes to an interface on the switch
and the switch/vrouter does not have an IP route back to the sender.
Check to see if no routes is increasing.

IE:

sun.250(vSwitch-e-commerce vRouter-default)# show ip statistics
In Receives:                                   4925637
In Header Errors:                              0
In Address Errors:                             0
Pkts Routed:                                   4925614
Unknown Protos:                                38874
In Pkts Discarded:                             0
In Pkts Delivered:                             5005844
In IP Options:                                 0
Out Requests:                                  7482149
Out Discards:                                  0
Out No Routes:                                 70   <----Out no Routes increase

To correct the problem, insure that the vrouter has a route back
to the system that is sending the ICMP echo request, or disable
the application that is sending the ICMP echo request.



Relief/Workaround




Product
Sun Secure Application Switch - N2000 Series
Sun Secure Application Switch - N1000 Series

Internal Comments
For internal Sun use only.

Systems TSC Tech Domain (former PTS) Product Page http://rsd-software.sfbay/products/nauticus


N2000, N1400, Event
Previously Published As
86871

Change History
Date: 2006-09-11
User Name: 31620
Action: Approved
Comment: Verified Metadata
- ok
Verified Keywords - ok
Verified still correct for audience - currently set to contract
Audience left at contract as per FvF at
http://kmo.central/howto/content/voyager-contributor-standards.html
Checked review date - currently set to 2007-09-07
Checked for TM - none needed
Publishing under the current publication rules of 18 Apr 2005:
Version: 3
Date: 2006-09-07
User Name: 31620
Action: Accept
Comment:
Version: 0
Product_uuid
73079c92-05ad-11d9-81ac-080020a9ed93|Sun Secure Application Switch - N2000 Series
c42f9435-d3a4-11d9-8a74-080020a9ed93|Sun Secure Application Switch - N1000 Series

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback