![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1008065.1 : Secure Application Switch log fills with ICMP echo reply failed
PreviouslyPublishedAs 211106 Symptoms The Secure Application Switch log fills with messages like this: ID Date Level Subsystem Message 10271 9/7/2006-08:41:00 warning IP 101a9: ICMP echo reply failed - IP unable to send to 10.1.50.4 10269 9/7/2006-08:40:55 warning IP 101a9: Last message repeated 4 times 10268 9/7/2006-08:40:55 warning IP 101a9: ICMP echo reply failed - IP unable to send to 10.1.50.4 Resolution The problem is usually caused by some application that is sending ICMP echo request such as IPMP probes to an interface on the switch and the switch/vrouter does not have an IP route back to the sender. Check to see if no routes is increasing. IE: sun.250(vSwitch-e-commerce vRouter-default)# show ip statistics In Receives: 4925637 In Header Errors: 0 In Address Errors: 0 Pkts Routed: 4925614 Unknown Protos: 38874 In Pkts Discarded: 0 In Pkts Delivered: 5005844 In IP Options: 0 Out Requests: 7482149 Out Discards: 0 Out No Routes: 70 <----Out no Routes increase To correct the problem, insure that the vrouter has a route back Relief/Workaround Product Sun Secure Application Switch - N2000 Series Sun Secure Application Switch - N1000 Series Internal Comments For internal Sun use only. Systems TSC Tech Domain (former PTS) Product Page http://rsd-software.sfbay/products/nauticus N2000, N1400, Event Previously Published As 86871 Change History Date: 2006-09-11 User Name: 31620 Action: Approved Comment: Verified Metadata - ok Verified Keywords - ok Verified still correct for audience - currently set to contract Audience left at contract as per FvF at http://kmo.central/howto/content/voyager-contributor-standards.html Checked review date - currently set to 2007-09-07 Checked for TM - none needed Publishing under the current publication rules of 18 Apr 2005: Version: 3 Date: 2006-09-07 User Name: 31620 Action: Accept Comment: Version: 0 Product_uuid 73079c92-05ad-11d9-81ac-080020a9ed93|Sun Secure Application Switch - N2000 Series c42f9435-d3a4-11d9-8a74-080020a9ed93|Sun Secure Application Switch - N1000 Series Attachments This solution has no attachment |
||||||||||||
|