Solution Type  Problem Resolution Sure

Solution  1008040.1 :   Sun[TM] Secure Application Switch delivers "All Retries Attempted" page  


Related Items
  • Sun Network Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Interfaces
  •  

PreviouslyPublishedAs
211078


Symptoms
The http virtual service of a Sun[TM] Secure Application Switch (n1000 or n2000 series) delivers an "All Retries Attempted" page.

It has exhausted all the retries and sends a close to the client that is requesting. The server has not replied to the requests for each of the retries attempted. Once exhausted we send a close stating all retries attempted.



Resolution
The only way to get this under control is to get the real services situation in sync to what the server health checks (SHC) detect.

This may include to change the SHC probe type or timing.
E.g. a SHC using ICMP probe type may still show up, even if the http service on the host is not responding.

More information on changing SHC is on
http://www.sun.com/products-n-solutions/hardware/docs/Network_Connectivity/secure_app_switches/
(Configuration and Implementation Guide - How to Configure Server Health Checks)
and
http://www.sun.com/products-n-solutions/hardware/docs/html/819-3047-10/
(Command Line Interface (CLI) help)



Relief/Workaround




Additional Information
This behavior appears if an http virtual service connects an appareantly active real service, but the host does not respond. In this situation, the switch generates a web page used as response which contains the string "All Retries Attempted".


Product
Sun Secure Application Switch - N2000 Series
Sun Secure Application Switch - N1000 Series

Internal Comments
TSC Technology Domain (former PTS) Product page:

http://rsd-software.sfbay/products/nauticus


Reference to nauticus-interest archive


nauticus
Previously Published As
86468

Change History
Date: 2006-08-18
User Name: 95826
Action: Approved
Comment: - verified metadata
- review date ok : 2007-08-27
- checked for TM - none added
- checked audience : contract
Publishing
Version: 3
Date: 2006-08-17
Product_uuid
73079c92-05ad-11d9-81ac-080020a9ed93|Sun Secure Application Switch - N2000 Series
c42f9435-d3a4-11d9-8a74-080020a9ed93|Sun Secure Application Switch - N1000 Series

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback