Symptoms
The system LED (both on the front panel and on the ALOM card) is not lit.
According to the system documentation, the system LED should be lit when
the OS is running and the LOMlite2 software is loaded.
Cause
Inappropriate LED setting.
Solution
Resolution
There are 3 alarms defined on the LOMlite2 card.
However; there are only 2 alarm LED's present.
For a depiction of these LED's refer to:
Netra 20 LEDs
The third alarm manifests itself as the system LED.
Turning on alarm3 will extinguish the system LED.
Turning off alarm3 will light the system LED.
To resolve the problem; log into the ALOM card and issue
lom> alarmoff 3
Product
Netra 20 Server
netra, lomlite2, system, led
Previously Published As
82664
Change History
Date: 2005-10-12
User Name: 7058
Action: Approved
Comment: Changed audience of this document to internal only because the SSH link reference is to an internal only location.
Trademarked where needed.
Fixed missing punctuation.
OK to publish.
Version: 4
Date: 2005-10-11
User Name: 7058
Action: Accept
Comment:
Version: 0
Date: 2005-10-11
User Name: 116519
Action: Approved
Comment: Final review warranted.
Version: 0
Date: 2005-09-26
User Name: 113097
Action: Approved
Comment: updated with URL per TR request.
Version: 0
Date: 2005-09-26
User Name: 116519
Action: Rejected
Comment: Sending back.
Version: 0
Date: 2005-09-20
User Name: 85696
Action: Add Comment
Comment: Could you add a URL to point to a Diagram of the LEDS so we understand what
LEDS we are talking about
http://scsh280r1.holland.sun.com/handbook_internal/General/LEDs/Netra20_LEDs.html
Version: 0
Date: 2005-09-20
User Name: 116519
Action: Accept
Comment:
Version: 0
Date: 2005-09-20
User Name: 113097
Action: Approved
Comment: Please review based on experiences in the field.
Version: 0
Date: 2005-09-20
User Name: 113097
Action: Created
Comment:
Version: 0
Product_uuid
29aa2760-0a18-11d6-9ba6-ecdc03b9c8f5|Netra 20 Server