![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1007010.1 : SL8500 - Defective EPO Switch Cable Assembly
PreviouslyPublishedAs 209685 Oracle Confidential PARTNER - Available to partners (SUN). Reason: Confidential information provided to Oracle and Partner Service Personnel Applies to:Sun StorageTek SL8500 Modular Library System - Version Not Applicable and laterAll Platforms SymptomsDefective EPO Switch Cable assembly results in no rail power applied to the library. This can be detected by the following symptoms: * No S-bot movement. * Green LEDs on the rail power supply not illuminated. * Green rail power LED (left most LED as observed from the rear of the library) on all HBF cards not illuminated. CauseDefective EPO Switch Cable Assembly. SolutionSteps to Follow Both front panel and internal EPO switches can be shorted using a jumper wire to help determine if the EPO switches are defective. * Disconnect internal EPO switch cable connector (J719) from the 4-pin mating connector labeled P719. * Using a jumper wire, short pin 1 on P719 (this pin is connected to the red wire) to pin 2 on P719 (this pin is connected to the black wire). Caution: * Disconnect front panel EPO switch cable connector (J752) from the 2-pin mating connector labeled P752. * Using a jumper wire, short pins 1 and 2. These pins are connected to white and black wires respectively. * Close library doors and apply power to the library. If rail power is applied, s-bot movement will be observed. Note: Permanent Solution: Attachments This solution has no attachment |
||||||||||||
|