Solution Type Problem Resolution Sure Solution 1006470.1 : WARNING: kbd: Too many keys down! messages and bad keyboard behavior in Ultra[TM] 60/80
PreviouslyPublishedAs 209065 Applies to:Sun Ultra 60 Workstation - Version Not Applicable and laterSun Ultra 80 Workstation - Version Not Applicable and later All Platforms SymptomsOn Ultra[TM] 80 or Ultra[TM] 60, a defective audio module may cause bad behavior of keyboard. CauseThe cause of this issue has been identified as a faulty Audio Module SolutionFor example:
This behavior was observed in systems with latest firmware - OBP 3.31.0 2001/07/25 20:31 POST 2.0.3 2000/07/31 15:28
Please open an Oracle Service Request for verification of a need for an Audio Module and/or further diagnostics.