Sun Fire[TM] V250 may falsely report fan failures
Related Categories |
- PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-V2x0
- _Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
|
PreviouslyPublishedAs
209027
Applies to:
Sun Fire V250 Server - Version Not Applicable and later
All Platforms
Symptoms
A health check is run every 24 hours on the fans. Sometimes during this test
an incorrect fan speed is read leading to a fan being marked as faulty when it
is not.
Cause
N/A
Solution
A message is displayed on the console, indicating that a fan has faulted:
"ENCLOSURE_FAN @ FT1.F0.RS has FAULTED."
OR
"ENCLOSURE_FAN @ FT2.F0.RS has FAULTED."
This message is incorrect as the fan is not faulty, it is just the fan speed
reading that was wrong.
Resolution
This problem has been fixed in Sun Advanced Lights Out Manager (ALOM) 1.5.
To check the ALOM version run the following command.
/usr/platform/SUNW,Sun-Fire-V250/sbin/scadm version
The ALOM 1.5. software and documentation can be downloaded from Sun Download Center
Additional Information
The problem is documented in <BUG: 15183394>