Solution Type Problem Resolution Sure Solution 1004787.1 : RSC loghistory shows disk failure, disk ok on Sun Fire [TM]280R
PreviouslyPublishedAs 206646 Applies to:Sun Fire 280R Server - Version Not Applicable and laterAll Platforms SymptomsOn the Sun Fire[TM] 280R, if the RSC card is configured properly, the log history during a boot will show a disk as having failed and then reports it as ok:
NOV 26 14:36:29 e280r-hw: 00040002: "Host System has Reset"
NOV 26 14:36:30 e280r-hw: 0004000b: "Host System has read and cleared bootmode." NOV 26 14:36:54 e280r-hw: 00010000: "Disk 0 Failure." NOV 26 14:37:54 e280r-hw: 00010001: "Disk 0 OK." CauseDisk being checked before it is completely spun up. Solution
To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - SPARC Legacy Servers
What is happening is the disk is not ready to be probed but the system is looking for the disk. The system finds the disk, but it has not fully spun up, therefore it reports the disk as having a failure.
NOV 26 14:36:54 e280r-hw: 00010000: "Disk 0 Failure."
Once the disk has gotten to full speed the system sees the disk as ok and reports it as:
NOV 26 14:37:54 e280r-hw: 00010001: "Disk 0 OK."
The disk has not failed,. no need to replace.