1004035.1
:
Subnetmask Not Saved by 'configupload' in Brocade Switches
Related Items |
- Brocade 200E Switch
- Brocade 3250 Fabric Switch
- Brocade 3800 Fabric Switch
- Brocade 3850 Fabric Switch
- Brocade 3900 Switch
- Brocade 48000 Director
- Brocade 24000 Director
- Brocade 12000 Fabric Switch
- Brocade 4100 Switch
- Brocade SAN Switch Hardware
|
Related Categories |
- PLA-Support>Sun Systems>DISK>Switch>SN-DK: Brocade Switch
- _Old GCS Categories>Sun Microsystems>Switches>Brocade
|
PreviouslyPublishedAs
205627
Applies to:
Brocade 12000 Fabric Switch - Version Not Applicable and later
Brocade 200E Switch - Version Not Applicable and later
Brocade 24000 Director - Version Not Applicable and later
Brocade 3250 Fabric Switch - Version Not Applicable and later
Brocade 3800 Fabric Switch - Version Not Applicable and later
All Platforms
Symptoms
Subnetmask not saved by 'configupload' in Brocade switches
Cause
Brocade switches uses the 'configupload' command to backup switch configuration such as IP address and zone settings. If a switch is replaced, customer can use configdownload command to restore original switch configuration.
Subnetmasks are set via the 'ipAddrSet' command and verified via the 'ipAddrShow' command. Below is an example.
sw3900a:root> ipAddrSet
Ethernet IP Address [129.X.X.106]:
Ethernet Subnetmask [255.255.255.0]: 255.255.255.128
Fibre Channel IP Address [0.0.0.0]:
Fibre Channel Subnetmask [0.0.0.0]:
Gateway IP Address [129.X.X.112]:
IP address being changed...
Committing configuration...Done.
sw3900a:root> ipAddrShow
Ethernet IP Address: 129.X.X.106
Ethernet Subnetmask: 255.255.255.128 <==== subnetmask
Fibre Channel IP Address: 0.0.0.0
Fibre Channel Subnetmask: 0.0.0.0
Gateway Address: 129.X.X.112
Due to bugid 6395973, Brocade switches configupload command does not save subnetmask setting of the switch. This leads to problem when customer replaced a switch and restore switch settings via the configdownload command. The bug has not been fixed as of FOS 5.0.3.
Solution
The workaround is to run ipAddrSet to set the correct subnetmask after switch setting is restored via the configdownload command.
Service Request ID: 10816662
Escalation ID: 1-15302673
Solution ID: 1-15977228
Owner GEO: APAC
Customer GEO: APAC
Brocade, subnetmask, configupload, configdownload, ipAddrSet, ipAddrShow
Previously Published As
85091
Change History
Date: 2006-04-06
User Name: 142418
Action: Add Comment
Comment: Guy's,
This is a Bug ID and therefore should NOT be an Info Doc. What's going to happen to this Info Doc when a fix is available? Creating duplicate Information that has a good chance to be obsolete relatively quickly does not help us. I suggest not publishing this Ifo Doc. If people are searching Sun Solve for this issue, they will get a hit on the Bug ID and they will see the work around in it. This is unnecessary.
Thanks,
Paul Mazzarella
Version: 0
Date: 2006-03-29
User Name: 111868
Action: Approved
Comment: changed audience from free to contract
publishing
Version: 4
Date: 2006-03-28
User Name: 111868
Action: Accept
Comment:
Version: 0
Date: 2006-03-28
User Name: 109562
Action: Approved
Comment: Repeat of Info from Bug 6395973
Version: 0
Date: 2006-03-26
User Name: 109562
Action: Accept
Comment:
Version: 0
Date: 2006-03-26
User Name: 35723
Action: Approved
Comment: Re-submit for tech-review.
Version: 0
Date: 2006-03-26
User Name: 35723
Action: Rejected
Comment: Fixed the title as symple text mark-up language does not apply to title.
Version: 0
Date: 2006-03-26
User Name: 35723
Action: Accept
Comment:
Version: 0
Date: 2006-03-26
User Name: 35723
Action: Approved
Comment: Please review.
Version: 0
Date: 2006-03-25
User Name: 35723
Action: Migrated
Comment: apollo 1-15977228 2006-03-24
Version: 0
Product_uuid
49311310-146b-11d7-870d-d17cb3a778c1|Brocade 12000 2 GB Switch
c5741319-fe44-11d9-a8ca-080020a9ed93|Brocade 48000 Director
dd0032a7-6698-11d9-a841-080020a9ed93|Brocade 4100 Switch
f4a61c18-557a-11d7-8ec5-9ccb03c88fd7|Brocade SilkWorm 3900 Switch
238622e0-665b-11d8-9e3a-080020a9ed93|Brocade SilkWorm 3850 Fabric Switch
46630362-52b2-11d8-9e3a-080020a9ed93|Brocade SilkWorm 3250 Fabric Switch
24f55d62-6656-11d8-9e3a-080020a9ed93|Brocade SilkWorm 24000 Director
48af8b63-fe46-11d9-a8ca-080020a9ed93|Brocade 200E Switch
bcad8c78-24f2-11d7-9662-8adfd6134f7c|Brocade FC-AL Switch Phase 1
dd2607e2-16a0-11d7-8364-e51f39fcf431|Brocade 6400 64-Port Switch
2717a51d-d786-11d8-8a52-080020a9ed93|Brocade 4.2.2 Firmware
12a1cf56-146b-11d7-8078-d16844bae958|Brocade 3800 2 GB 16-Port Switch
55c99ee1-f8fd-11d7-84cb-080020a9ed93|Brocade 2800 1 GB 16-Port Switch
f563d849-f8fb-11d7-84cb-080020a9ed93|Brocade 2400 1 GB 8-Port Switch
Attachments
This solution has no attachment