Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1003518.1
Update Date:2015-05-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  1003518.1 :   Resolving "NVRAM CRC Error: NVRAM Must be Reinitialized" on Sun StorEdge[TM] 3510 Array  


Related Items
  • Sun Storage 3511 SATA Array
  •  
  • Sun Storage 3310 Array
  •  
  • Sun Storage 3510 FC Array
  •  
  • Sun Storage 3320 SCSI Array
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Arrays>SN-DK: SE31xx_33xx_35xx
  •  
  • _Old GCS Categories>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
204945


Applies to:

Sun Storage 3310 Array - Version Not Applicable and later
Sun Storage 3320 SCSI Array - Version Not Applicable and later
Sun Storage 3510 FC Array - Version Not Applicable and later
Sun Storage 3511 SATA Array - Version Not Applicable and later
All Platforms

Symptoms

 The error message seen in the tip session window or the sscli session you would see the error "NVRAM CRC Error! NVRAM must be reinitialized".

Changes

 

The Storage Array Sun StorEdge[TM] 3510 (SE3510) is reset/rebooted/Power cycled.  

 

There is also a probability of this occurring even on SE3511 and SE3310.

 

Cause

Controller resets, Array power cycles, Firmware upgrades and other controller issues such as failed replacement actions.

 

Solution

When this happens, the array looses all its customized settings includingthe lun maps.

Normally, the customer would not be connected to the array using tip session, so the error may not be visible. But if the customer complains
that he looses all the luns on the host and has to manually map the luns when he resets the array, then the error may be apparent.

To confirm if the error is present, connect to the controller using tip and reset the array and check for the above error message. If you get the error
message, follow the action plan below to resolve the problem.

1. From the sccli, reset the nvram, example follows:-

  
# sccli
sccli: selected device /dev/rdsk/c1t216000C0FF8015C6d0s2 [SUN StorEdge3510 SN#0015C6]

sccli> reset nvram

Following warning appears along with a confirmation prompt, press y.
WARNING: The configuration of the array controller will be erased.
Factory default parameters will take effect at next controller reset.
Logical devices may not be accessible until mappings are reconfigured.

Are you sure? y
 

The NVRAM is reset and is on factory settings now.

2. Power cycle the SE3510 and see if the NVRAM error message still appears.

3. If it does not appear, please go to (6) below.

4. If the error still appears, replace the controller.

Note: Please upgrade the controller firmware along with SES/PLD firmware on the newly replaced controller, if needed.

5. If the NVRAM error does not appear, copy the NVRAM from the disk back tothe controller I.E. Restore NVRAM from disk as follows:-

   RESTORING THE NVRAM CONFIGURATION
   From a Tip Session on the Firmware Menu
   ---------------------------------------
    a. Choose >system Functions>Controller maintenance>Restore nvram from disks.
         Note: A confirmation message appears.
    b. Press Yes to confirm.

Note: A prompt notifies you that the controller NVRAM data has been successfully restored from disks.

6. Check if everything works fine (we can reset the array and see if the error appears).

It may be the configuration restored form disk is not up to date or perhaps correct.  Manually reconfigure the settings if needed. 

Most likely, for this error, replacing the controller would only work but it may be worth trying to see if restoring NVRAM to factory defaults works thereby avoiding a controller replacement.



Product
Sun StorageTek 3511 SATA Array
Sun StorageTek 3510 FC Array
Sun StorageTek 3310 SCSI Array
Sun StorageTek 3320 SCSI Array

Internal Comments
For Internal Sun Use Only

 

Please see bug 5072698 Getting "NVRAM CRC Error! NVRAM must be reinitialized" on SE3510 while resetting.
NVRAM, CRC, SE3510, sccli, reset
Previously Published As
77390

 

Change History
Date: 2004-07-15
User Name: C139400
Action: Approved
Comment: corrected title, spelling, usage, format, taken out of first person, applied KE procedures
Version: 0
Date: 2004-07-15
User Name: C139400
Action: Accepted
Comment:
Version: 0
Attachments
This solution has no attachment