Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1003495.1
Update Date:2018-01-10
Keywords:

Solution Type  Problem Resolution Sure

Solution  1003495.1 :   Sun Enterprise[TM] 10000: DR operation error: "Can't clnt_create: hostname: RPC: Rpcbind failure - RPC: Timed out"  


Related Items
  • Sun Enterprise 10000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: SF-Exxk
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
204915


Applies to:

Sun Enterprise 10000 Server - Version Not Applicable and later
All Platforms

Symptoms

 An attempt to perform a Dynamic Reconfiguration (DR) operation on a Sun Enterprise[TM] 10000 domain results in the following output:

Checking environment...
Establishing Control Board Server connection...
Initializing SSP SNMP MIB...
Establishing communication with DR daemon...
Can't clnt_create: xxxxxxx: RPC: Rpcbind failure - RPC: Timed out
Error: can't communicate with DR daemon.
RPC setup failure. Check DR host daemon. Unable to continue.

Changes

 

Cause

 The output indicates that the SSP can't communicate with the target Sun Enterprise 10000 domain.

Solution

Check /etc/hosts to ensure the IP address of the SSP and the domain are correct on both the domain and the SSP. If they are not, then this is the error condition you will see.

Additional Information
Also refer to:
Document: 1004770.1 "Sun Enterprise[TM] 10000: Error: can't communicate with DR daemon."

Keywords: e10k, 10000, dr, clnt_create, rpcbind, failure

Previously Published As 76831


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.