![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type FAB (standard) Sure Solution 1156243.1 : FAB: Reactive: Pass-Through NEMs not Visible in CMM due to Incorrect Fruid Data
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun Netra 6000 System - Version Not Applicable to Not Applicable [Release N/A]Sun Blade 6000 System - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. ***Checked for relevance on 21-Jan-2014*** _________ Affected Parts: (FRU/CRU Part Number / Description) 371-1451 - 10-Port Gigabit Ethernet Network Express Module (X4250A) SymptomsYou will not see NEM type and fruid information in the CMM BUI component screens if you attempt to view fruid data from CMM CLI commands. For example: show / -l all: /CH/NEM1 Targets: PRSNT STATE Properties: type = Network Express Module ipmi_name = NEM1 Example of what a programmed NEM looks like: /CH/NEM0 Targets: PRSNT Properties: type = Network Express Module ipmi_name = NEM0 fru_name = ASSY,BD,NEM,6000 fru_part_number = 371-1451-04 fru_serial_number = 0000000-0828YF1287. Power monitoring on the CMM may show 0 Watts as a value because CMM doesn't know what kind of NEM is installed without fruid data: /CMM/powermgmt/advanced/22 Targets: Properties: name = NEM1 Allocated Power unit = Watts value = 0
ChangesContributing Factors ipmitool -H <ipaddressofCMM> -U root fru CauseRoot Cause SolutionWorkaround
Attached is a .pdf doc with the detailed directions. The generic .bin file needed to program the fruid is available via the below knowlege article; Sun Blade 6000/6048 Modular System Product Issues (Doc ID 1361822.1) References Modification History: 21-Jan-2014: Maintenance check for relevance/currency, no change in content Attachments This solution has no attachment |
||||||||||||||||||
|