![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type FAB (standard) Sure Solution 1000920.1 : FCO A0285-1: On certain Sun Systems a small number of 512MB and 1GB Micron DIMMs may experience premature failures with Uncorrectable Memory Error (UE) messages.
PreviouslyPublishedAs 201233 ***Checked for relevance on 21-Aug-2013*** Part
Impact Sun has identified a set of 512MB and 1GB Micron DIMMs that may experience early life failures displayed as uncorrectable memory error (UE) messages. Only a subpopulation of the 11 week date code range of 512MB and 1GB DIMMs are affected. The described issue typically occurs during the first 400 hours of memory module usage. All suspect Micron DIMMs were integrated into systems or X-Option orders, or as FRU stock into the RSLs between the dates of January 31, 2007 and May 31, 2007. Although DIMMs having a date code of 0715 or later are not affected, systems and xoptions that had already completed factory build/test were not purged and may have shipped as late as May 31, 2007. DIMMs with part number of 501-7385-01 or 501-7386-01 shipped before January 31, 2007 or after May 31, 2007 are not considered suspect. DIMMs manufactured by other than Micron are not impacted by this issue. Contributing Factors This issue can occur in the following Micron DIMMs:
The following SPARC Platforms and Products are known to be affected: Systems, X-Options, and FRU stock shipped between the dates of January 31, 2007 and May 31, 2007 with part number 501-7385 512MB DIMMs or part number 501-7386 1GB DIMMs within the following Model Numbers... Sun Fire V490/V890/V480/V880/V1280/280R Sun Fire 3800/48x0/6800 Sun Fire E2900/E4900/E6900/E20K/E25K/F12K/F15K Sun Blade 1000/2000 Netra 20/1280 X7051A 2GB (4x512MB SDRAM DIMMs) FRU p/n 501-7385 X7056A 4GB (4x1GB SDRAM DIMMs) FRU p/n 501-7386 Note: This may not be an exhaustive list of systems these DIMM part numbers are supported in and which may, therefore, be impacted by affected DIMMs from Services Spares. Symptoms Multiple uncorrectable memory failures in a single machine, and sample specific strings including: Multiple Softerrors Sticky Softerrors accumulated ... unix: [ID 340762 kern.notice] from Memory Module ... Uncorrectable system bus (UE) Event on CPU0 Privileged Data Access at ... WARNING: [AFT1] EDU Event on CPU0 ...ECC errors .. WARNING: [AFT1] WDU Event on ...UE EDU WDU Error(s)... NOTE: The specific error messages a customer will see will be dependent on the version of Solaris being run. Solaris 8, 9, and 10 all vary to some degree with the error messages logged at the time of these errors. Root Cause The affected Micron DIMMs were manufactured in an anomalous process which has proven to enhance the likelihood of early life failures of the DRAMs on the DIMMs. The anomalous process was corrected at the vendor and all DIMMs shipped after May 31, 2007 are not affected. Manufacturing was purged of all affected DIMMs via StopShip/Purge P001-20398 as of May 31, 2007. All Service Regional Stocking Locations (RSLs) were purged of affected material via GSAP 3959 starting on June 29, 2007. DIMM Tray FRU Kits, containing 25 DIMMs each, were released via ECO WO_37917. These 25 x DIMM Tray FRUs should only be used in the implementation of this FAB. Implementation Target Completion Dates: AMER: March 7, 2009 APAC: March 19, 2009 EMEA: March 19, 2009 Replacement Time Estimate: 30 minutes Resolution Hot Swappable: No Important: As of March 19, 2009 the implementation of this FCO changed from Proactive (Mandatory) to Reactive (Upon Failure). Upon Failure only replace as follows:
For orders equal to or greater than 25 DIMMs for per part number order as follows:
Example 1: If customer has 28 affected 512MB DIMMs you should order the following: 1 x 511-1030 and 3 x 501-7385 Example 2: If customer has 26 affected 512MB DIMMs and 12 affected 1GB DIMMs you should order the following: 1 x 511-1030, 1 x 501-7385, and 12 x 501-7386 Note: Tray FRUs will be in Micron shipping boxes versus Sun boxes. Individual DIMM FRUs will however continue to be in normal Sun packaging. IMPORTANT NOTE: Not all DIMMs PN# 501-7385-01 and 501-7386-01, on a listed System or UniBoard, are affected by this FCO. Please be sure to verify that ONLY affected DIMMs are replaced by following the identification instructions of this FCO. Identification of Affected Parts (how to): Sun Service Representatives and those with access inside of SWAN should use the showfru command to determine how many DIMMs are impacted by this issue. This tool can be acquired via the below (Internal Only) website; http://panacea.uk.oracle.com/twiki/bin/view/Tools/ToolPageShowfru For those who do not have SWAN access, open a Case against the System Serial Number with the Call Center and request an analysis of the FRU data from the Call Center Engineer responsible for the Case based on Explorer data. The Affected DIMM List can be viewed via the below URL; http://sdpsweb.central.sun.com/FIN_FCO/FCO/A0285-1/SPE/NGDIMM_SN.txt In addition, a Sun Legal approved Customer Letter is available via the below URL; http://sdpsweb.central.sun.com/FIN_FCO/FCO/A0285-1/SPE/Customer_Letter.odt Modification History Date: 21-Aug-2013
Date: 07-DEC-2007 Date: 18-DEC-2007 Previously Published As 103004 Internal Comments Hardware Remediation Details This FCO will have a time zone phased release based on material readiness as follows: Timezone Readiness Date -------- -------------- US/Canada Ready Ltn America Ready EMEA Dec/19/2007 APac Ready ANZO Ready Japan Dec/19/2007 The above dates represent when each time zone has determined that it will be materially ready to support this FCO. All dates are estimates. Check with your Logistics Representative or TZ / Country / Area FCO Manager for more information with regard to material availability and the parts ordering process for this FCO. Related Information
Internal Contributor/submitter Kevin.Siebenthal@Sun.COM Internal Eng Business Unit Group SSG ES (Enterprise Systems) Internal Eng Responsible Engineer Kevin.Siebenthal@Sun.COM Internal Services Knowledge Engineer Joe.Davis@Sun.COM Internal Kasp FAB Legacy ID 103004 Internal Sun Alert & FAB Admin Info Critical Category: Significant Change Date: 2007-07-18, 2007-12-07 Avoidance: Hardware Replacement Responsible Manager: Jack.Conroy@Sun.COM Original Admin Info: WF - received draft on 7/11/07 while I was on vacation. Began draft upon my return. Awtg sponsor reply on some questions. - Joe 7/12/07 WF - all questions resolved, sending to Ext Rvw. - Joe 7/13/07 WF - question from Don Palko (TSC) forwarded onto Leynette and Kevin to answers. - Joe 7/13/07 WF - No response from Leynette or Kevin on Don's questions, so I sent both of them a reminder that this FAB is onhold until all questions are resolved. - Joe 7/18/07 WF - Issues/questions resolved. Sending to Publish. - Joe 7/18/07 WF - added the word "Hardware" to Synopsis. - Joe 7/19/07 WF - chgd wording for FCO release, sending to Tiger Team for initial review. - Joe 11/6/07 WF - added ECO to draft. - Joe 11/9/07 WF - added link to 'showfru' tool, awtg material readiness. - Joe 11/21/07 WF - added Important Note in Resolution section. - Joe 11/26/07 WF - added Target Completion Date field in Issue Description section & Hot Swap field in Resolution section. - Joe 11/28/07 WF - added Material Availability section with dates, and sending to Tiger Team for final review. - Joe 12/05/07 WF - Customer List loaded into SunFIT, sending to Pub. -Joe 12/7/07 WF - Corrected DIMM x25 Tray p/ns. - Joe 12/18/07 Product_uuid 234d3ae5-e13f-41e8-aa07-3bbbc6f63d05|512 MB DIMM Attachments This solution has no attachment |
||||||||||||
|