Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-73-1000523.1
Update Date:2018-01-09
Keywords:

Solution Type  FAB (standard) Sure

Solution  1000523.1 :   On Sun Fire X2200 M2 and X2100 M2, PC Check diagnostics only checks 9 DIMMs (or less) and the remainder DIMMs are untested. Another described issue results in false positive errors.  


Related Items
  • Sun Fire X2100 M2 Server
  •  
  • Sun Fire X2200 M2 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun FAB
  •  

PreviouslyPublishedAs
200666


__________

Product
Sun Fire X2100 M2 Server
Sun Fire X2200 M2 Server

Bug Id
<BUG: 15422557>


Impact

There are two issues described in this FAB document.

1) The PC check diagnostic scripts for memory only tests 9 DIMMs (or fewer depending on the configuration). If there are more than nine DIMMs it will not report in the event of a faulty DIMM and may result in other parts being replaced needlessly.

2) Additionally, PC Check versions (prior to 6.05b) in the Tools & Drivers may report false positive DIMM errors if run for several hours. False errors could cause unnecessary DIMM, motherboard or cpu replacements because the errors will persist with each diagnostic run, leading the field to replace non-affected parts.


Contributing Factors

For issue 1) above, memory check of DIMMs:

  • Sun Fire X2200 M2 prior to 1.5a CD

Note: This is the one server with more than 8 DIMMs by default.

For issue 2) above, false positive DIMM errors:

  • Sun Fire X2200 M2 prior to 1.4 CD
  • Sun Fire X2100 M2 prior to 1.3 CD

Symptoms

1) Test scripts give no symptom or indication that configurations with more than nine DIMMs are not tested.

2) Here are 2 examples of false positive error messages:

    Failed Disk Test
    Failed Memory Test

 


Workaround

See CR 6603341 for details on a possible workaround for issue 1). Please contact engineering as needed if a workaround is necessary until the resolution below can be implemented.


Resolution

1) For X2200M2 with more than 9 DIMMS:

  • Tools & Drivers 1.5a CD

We recommend downloading the latest updates which include the latest SP, BIOS, and PC Check versions at:

2) To correct the false positive errors:

For X2200M2 download the 1.4 CD from:

For X2100M2 download the 1.3 CD from:

 


Modification History:

04-Nov-2014: Maintenance check for relevance/currency, no change in content

Previously Published As: 103126

Internal Comments

There was no CR for the false memory errors.


There is Bug 6456755 that is very similar but that was for Andromeda and does not mention the X2200 M2 or other platforms.


Business Unit Group: X86 Systems Group
Internal Contributor/submitter: Kim.Mayman@oracle.COM
Internal Eng Business Unit Group: NSG (Network Systems Group)
Internal Eng Responsible Engineer: michael.laflamme@oracle.com
Internal Services Knowledge Engineer:

Internal Kasp FAB Legacy ID: 103126

Internal Sun Alert & FAB Admin Info
Critical Category:
Significant Change Date: 2007-10-25
Avoidance: Upgrade
Responsible Manager: chenhao.geng@sun.com
Original Admin Info: WF 23-Oct-2007 created and sending for review karen