Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Oracle ZFS Storage Appliance Racked System ZS5-4 (X5-4 Server): Hardware Specifications

Processor
Number 4 Processors
Architecture Type: Intel Xeon E7-8895 v3 Processors
CPUs Intel 2.6GHz 18-Core Xeon E7-8895 v3, 175W
Main Memory
Capacities
  • 4 Processor - 96 DIMM slots
  • DIMM Size and Type: 16GB: DDR3L-1600/PC3L-12800 Registered DIMMs
  • 4 Processor - Maximum Memory Capacity: 1.5TB using 16GB DIMMs in 96 slots
Standard I/O
Network Four auto-negotiating 10 Gigabit Ethernet (GbE) ports (RJ-45 connector).
Network Management One 10/100/1000Base-T Network Management (NET MGT/RJ-45 connector) port
Serial Management One serial console (SER MGT/RJ-45 connector) port.
USB Rear: 2 USB 2.0 Ports
Front: 2 USB 2.0 Ports
Internal: 2 USB 2.0 Ports
Video One VGA 2D embedded graphics controller with DB-15 connector. Resolution: 1,600 x 1,200 x 16 bits @ 60 Hz. 1,024 x 768 when viewed remotely via Oracle ILOM.
I/O Expansion Eleven PCI Express 3.0 Slots:
  • 9 slots are x8 PCIe slots (1 - 7, 9, & 10)
  • 2 slots are x16 PCIe slots (8 & 11)
  • Base ZS5-4 always populates the following slots/cards: PCIe Slot 4 Clustron 3, PCIe Slot 2 Estes-Int, PCIe Slots 6 & 7 Thebe3
Internal Mass Storage
Disks Six front-accessible and hot-swappable 2.5" SAS disk bays (Only two drive bays are populated HDD0 and HDD1).
Remainder of drive bays are populated with filler panels.

Drive Location
Density
Speed
Form Factor
X5-4 Controller
1.2TB
10,000 RPM
2.5"

Power Supplies and Fans
  • Two hot-swappable power supplies with N=N redundancy.
Environment
Power Consumption Online power calculator
AC power Operating input voltage range: 100 to 127 VAC (2-CPU configuration); 200 to 240 VAC (2-CPU or 4-CPU configuration)
Rated input current 100 to 127 VAC 12A and 200 to 240 VAC 10A.
Temperature Operating: 5° C to 35° C (41° F to 95° F) (sea level); 5° C to 31° C (41° F to 88° F) (at altitude)
Nonoperating: -40° C to 68° C (-40° F to 154°F)
Humidity Operating: 10% to 90% relative humidity noncondensing.
Nonoperating: Up to 93% relative humidity noncondensing
Altitude Operating: Up to 3,000 m (9,840 ft.) maximum operating temperature is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft), except in China where regulations might limit installations to a maximum of 2000 m (6562 ft).
Nonoperating: Up to 12,000 m (39,370 ft.)
Maximum Power Consumption 2000W
Maximum Heat Output 6824 BTU/hr
Acoustic Noise LwAd: 8.9 B (idle and operating, room temp.), 8.9 B (max. ambient); LpAm: 75 dBA (bystander position,
max. ambient)
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA-60950-1, EN60950-1, IEC60950-1 CB scheme with all country differences.
EMC Emissions: FCC 47 CFR Part 15, ICES-003, EN55022, EN61000-3-2 and EN61000-3-3.
Immunity EM55024
Certifications
  • North America Safety (NRTL)
  • European Union (EU)
  • International CB Scheme
  • BIS (India)
  • BSMI (Taiwan)
  • RCM (Australia)
  • MSIP (Korea)
  • VCCI (Japan)
European Union Directives
  • 2014/35/EU Low Voltage Directive
  • 2014/30/EU EMC Directive
  • 2011/65/EU RoHS Directive
  • 2012/19/EU WEEE Directive
Dimensions and Weight
Height 129.9 mm (5.1 in.)
Width 436.5 mm (17.2 in.)
Depth 732 mm (28.8 in.)
752.35 mm (29.6 in) with PSU ejectors
Weight Maximum: 40 kg (88 lbs.)
Rack Mounting
Clearances Front: 1232 mm (48.5 in)
Rear: 914 mm (36 in)
Oracle ZFS Storage ZS5-4 Racks
  • Oracle Redwood II 42U-1200 Rack
  • Tooless rackmounting slide rail kit.
  • Cable management arm.

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
 Feedback