Processor |
Number |
4 Processors |
Architecture |
Type: Intel Xeon E7-8895 v3 Processors |
CPUs |
Intel 2.6GHz 18-Core Xeon E7-8895 v3, 175W
|
Main
Memory |
Capacities |
- 4 Processor - 96 DIMM slots
- DIMM Size and Type: 16GB: DDR3L-1600/PC3L-12800 Registered DIMMs
- 4 Processor - Maximum Memory Capacity: 1.5TB using 16GB DIMMs
in 96 slots
|
Standard
I/O |
Network |
Four auto-negotiating 10 Gigabit Ethernet (GbE) ports (RJ-45 connector). |
Network Management |
One 10/100/1000Base-T Network Management (NET MGT/RJ-45 connector) port |
Serial Management |
One serial console (SER MGT/RJ-45 connector) port. |
USB |
Rear: 2 USB 2.0 Ports
Front: 2 USB 2.0 Ports
Internal: 2 USB 2.0 Ports |
Video |
One VGA 2D embedded graphics controller with DB-15 connector. Resolution:
1,600 x 1,200 x 16 bits @ 60 Hz. 1,024 x 768 when viewed remotely via Oracle
ILOM. |
I/O Expansion |
Eleven PCI Express 3.0 Slots:
- 9 slots are x8 PCIe slots (1 - 7, 9, & 10)
- 2 slots are x16 PCIe slots (8 & 11)
- Base ZS5-4 always populates the following slots/cards: PCIe Slot 4 Clustron 3, PCIe Slot 2 Estes-Int, PCIe Slots 6 & 7 Thebe3
|
Internal
Mass Storage |
Disks |
Six front-accessible and hot-swappable 2.5"
SAS disk bays (Only two drive bays are populated HDD0 and HDD1).
Remainder of drive bays are populated with filler panels.
Drive Location
|
Density
|
Speed
|
Form Factor
|
X5-4 Controller
|
1.2TB
|
10,000 RPM
|
2.5"
|
|
Power
Supplies and Fans |
- Two hot-swappable power supplies with N=N redundancy.
|
Environment |
Power Consumption |
Online
power calculator |
AC power |
Operating input voltage range: 100 to 127 VAC (2-CPU configuration); 200
to 240 VAC (2-CPU or 4-CPU configuration)
Rated input current 100 to 127 VAC 12A and 200 to 240 VAC 10A. |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F) (sea
level); 5° C to 31° C (41° F to 88° F) (at altitude)
Nonoperating: -40° C to 68° C (-40° F to 154°F) |
Humidity |
Operating: 10% to 90% relative humidity noncondensing.
Nonoperating: Up to 93% relative humidity noncondensing |
Altitude |
Operating: Up to 3,000 m (9,840 ft.) maximum operating temperature
is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft),
except in China where regulations might limit installations to a maximum
of 2000 m (6562 ft).
Nonoperating: Up to 12,000 m (39,370 ft.) |
Maximum Power Consumption |
2000W |
Maximum Heat Output |
6824 BTU/hr |
Acoustic Noise |
LwAd: 8.9 B (idle and operating, room temp.), 8.9 B (max. ambient); LpAm:
75 dBA (bystander position,
max. ambient) |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB scheme with all country differences.
|
EMC |
Emissions: FCC 47 CFR Part 15, ICES-003, EN55022, EN61000-3-2 and EN61000-3-3.
|
Immunity |
EM55024 |
Certifications |
- North America Safety (NRTL)
- European Union (EU)
- International CB Scheme
- BIS (India)
- BSMI (Taiwan)
- RCM (Australia)
- MSIP (Korea)
- VCCI (Japan)
|
European Union Directives |
- 2014/35/EU Low Voltage Directive
- 2014/30/EU EMC Directive
- 2011/65/EU RoHS Directive
- 2012/19/EU WEEE Directive
|
Dimensions
and Weight |
Height |
129.9 mm (5.1 in.) |
Width |
436.5 mm (17.2 in.) |
Depth |
732 mm (28.8 in.)
752.35 mm (29.6 in) with PSU ejectors |
Weight |
Maximum: 40 kg (88 lbs.) |
Rack
Mounting |
Clearances
| Front: 1232 mm (48.5 in)
Rear: 914 mm (36 in) |
Oracle ZFS Storage ZS5-4 Racks
|
- Oracle Redwood II 42U-1200 Rack
- Tooless rackmounting slide rail kit.
- Cable management arm.
|