Processor |
Number |
Two Intel 18-Core |
Architecture |
Type: 18-Core Intel Xeon E5-2699 v3, 145W
|
Cache memory |
Level 1: 64 KB cache per core including 32 KB L1 data + 32 KB L1 instruction
Level 2: 256 KB shared data and instruction L2 cache per core
Level 3: Up to 8 MB shared inclusive L3 cache per processor
|
Main Memory |
Capacities |
Total DIMM slots: 24
DIMM type: 32GB LR DDR4-2133 or 16GB DDR4-2133 Registered DIMMs
Minimum Memory Capacity: 64GB using 32GB DIMMs or 32GB using 16GB DIMMs
Maximum capacity: 768GB using 32GB DIMMs or 384GB using 16GB DIMMs
|
Standard
Integrated Interfaces |
Network |
Four onboard auto-sensing 100/1000/10,000 BASE-T Ethernet (GbE) ports (RJ-45 connector) |
Network Management |
One 10/100/1000 Base-T Network Management (NET MGT/RJ-45 connector) port |
Serial Management |
One serial console (SER MGT/RJ-45 connector) port |
USB (2.0)
|
Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 (capable of 3.0) Ports
Internal: 2 USB 2.0 Ports
|
Graphics
|
One VGA 2D embedded graphics controller with DB-15 connector
Resolution: 1,600 x1,200x16 MB @ 60 Hz. 1,024 x 768 when viewed remotely via Oracle ILOM.
|
Alarms
|
Four fail-safe DB-15 dry contact (critical, major, minor and user)
|
I/O Expansion |
Six low profile PCIe 3.0 slots:
PCI-E slot 1: x16
PCI-E slot 2: x8
PCI-E slot 3: x8
PCI-E slot 4: x8
PCI-E slot 5: x16
PCI-E slot 6: x8
Note: The base ZS5-2 unit always populates Slot 4 with the Clustron 3 Heartbeat card and
Slot 2 with the 4x4-Port PCIe-3, 6Gbps SAS-2 HBA (Thebe2) card.
|
Internal Storage |
Disk Drives
|
Eight 2.5-inch SAS-3 front accessible, hot-swappable disk bays with no DVD-RW.
Populated with two 1.2TB 10K RPM SAS-3 Boot drives and Six HDD filler panels.
|
Attached Storage |
Disk Shelf Options 1 or 2
|
DE2-24C - Up to four SAS SSD's (Logzilla's)
and up to twenty 3.5" SAS HDD's. DE2-24P - Up to four SAS SSD's (Logzilla's)
and up to twenty 2.5" SAS HDD's.
|
Power Supplies |
Two 1,200W (1+1 Redundancy) AC and DC
Note: To ensure redundant
operation of the power supplies, the two power inputs should be
connected to separate power sources.
|
DC Power
|
Operating voltage: -40 to -72 VDC
|
AC Power
|
Operating voltage: 100 to 240 VAC
|
Environment |
Power Consumption |
Online power calculator |
Temperature |
Operating: 5° C to 45° C (41° F to
113° F)/Short term: 5° C to 55° C (23° F to 131° F)
Nonoperating: -40° C to 70° C (-40° F to
158° F)
|
Humidity |
Operating: 5% to 85% relative humidity noncondensing,
but not to exceed 0.024kg water/kg dry air (0.053 lbs.
water 2.205 lb. dry air)
Short term: 5% to 90% relative humidity
noncondensing, but not to exceed 0.024kg water/kg dry air (0.053 lbs.
water 2.205 lb. dry air)
Nonoperating: up to 93% relative humidity noncondensing,
40° C (104° F) max wet bulb
|
Altitude |
Operating: 0m to 3,000m (0ft to 9840ft.) Maximum ambient temperature is derated by 1 degree C
above 900 m, except in China where regulations may limit
installations to a maximum altitude of 2,000 m. |
Acoustic noise |
Operating/Idling Acoustic Noise less than 7.2B @ 25° C (LwAd, 1B=10dB) |
Regulations
Meets or exceeds the following
requirements: |
Safety |
UL 60950-1, EN60950-1, IEC60950-1 CB scheme with all country differences |
Emissions |
FCC CFR 47 Part 15, ICES-003, EN55024, EN61000-3-2 and EN61000-3-3, EN300-386 |
EMC (Immunity) |
EM55024 |
Certifications |
- North America Safety (NRTL)
- European Union (EU)
- International CB Scheme
- BIS (India)
- BSMI (Taiwan)
- RCM (Australia)
- CCC (PRC)
- MSIP (Korea)
- VCCI (Japan)
- EAC (Russia)
|
European Union Directives |
- 2006/95/EC Low Voltage Directive
- 2004/108/EC EMC Directive
- 2011/65/EU RoHS Directive
- 2012/19/EU WEEE Directive
|
Dimensions and Weight |
Height |
87.1 mm (3.43 in.) 2 RU
|
Width |
445 mm (17.52 in.) including mounting ears and without bezel 425.4 mm (16.75 in.)./td>
|
Depth |
maximum with PSU's: 640.0 mm (25.2 in.)
maximum w/o PSU's: 609.45 mm (24 in.)
|
Weight |
Approximate (fully populated)
17.5 kg (38.5 lb.)
|
Rack Mounting |
Rack Units
|
2
|
Rack Kits Available |
- 19" 4-Post Rackmount Brackets
- New Netra Chassis is 24" deep, 2U high
- Sun Rack 1242 support
- Sun Rack 1042 support
|
1 The slide kit includes hardware that
enables mounting to any of the following types of rack rails:
- 6 mm threaded holes
- #10-32 threaded holes
- #10 threaded holes
These must be compliant racks which have mounting
depths of 27-30 inches. |