Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Oracle ZFS Storage ZS5-2 Hardware Specifications

Processor
Number Two Intel 18-Core
Architecture Type: 18-Core Intel Xeon E5-2699 v3, 145W
Cache memory Level 1: 64 KB cache per core including 32 KB L1 data + 32 KB L1 instruction
Level 2: 256 KB shared data and instruction L2 cache per core
Level 3: Up to 8 MB shared inclusive L3 cache per processor
Main Memory
Capacities Total DIMM slots: 24
DIMM type: 32GB LR DDR4-2133 or 16GB DDR4-2133 Registered DIMMs
Minimum Memory Capacity: 64GB using 32GB DIMMs or 32GB using 16GB DIMMs
Maximum capacity: 768GB using 32GB DIMMs or 384GB using 16GB DIMMs
Standard Integrated Interfaces
Network Four onboard auto-sensing 100/1000/10,000 BASE-T Ethernet (GbE) ports (RJ-45 connector)
Network Management One 10/100/1000 Base-T Network Management (NET MGT/RJ-45 connector) port
Serial Management One serial console (SER MGT/RJ-45 connector) port
USB (2.0)
Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 (capable of 3.0) Ports
Internal: 2 USB 2.0 Ports
Graphics
One VGA 2D embedded graphics controller with DB-15 connector
Resolution: 1,600 x1,200x16 MB @ 60 Hz. 1,024 x 768 when viewed remotely via Oracle ILOM.
Alarms
Four fail-safe  DB-15 dry contact  (critical, major, minor and user)
I/O Expansion Six low profile PCIe 3.0 slots:
  • PCI-E slot 1: x16
  • PCI-E slot 2: x8
  • PCI-E slot 3: x8
  • PCI-E slot 4: x8
  • PCI-E slot 5: x16
  • PCI-E slot 6: x8

  • Note: The base ZS5-2 unit always populates Slot 4 with the Clustron 3 Heartbeat card and Slot 2 with the 4x4-Port PCIe-3, 6Gbps SAS-2 HBA (Thebe2) card.
    Internal Storage
    Disk Drives
    Eight 2.5-inch SAS-3 front accessible, hot-swappable disk bays with no DVD-RW.
    Populated with two 1.2TB 10K RPM SAS-3 Boot drives and Six HDD filler panels.
    Attached Storage
    Disk Shelf Options 1 or 2
    DE2-24C - Up to four SAS SSD's (Logzilla's) and up to twenty 3.5" SAS HDD's.
    DE2-24P - Up to four SAS SSD's (Logzilla's) and up to twenty 2.5" SAS HDD's.

    Part Number
    Part Description
    Form Factor
    Supported In
    Disks - ZFS Storage ZS5-2 (Netra X5-2 Controller - Marlin bracket)
    7093037 [C]
    1.2TB - 10000 RPM SAS Disk Drive Assembly
    2.5"
    Netra X5-2 Controller

    Power Supplies
    Two 1,200W (1+1 Redundancy) AC and DC
    Note: To ensure redundant operation of the power supplies, the two power inputs should be connected to separate power sources. 
    DC Power
    Operating voltage: -40 to -72 VDC
    AC Power
    Operating voltage: 100 to 240 VAC
    Environment
    Power Consumption Online power calculator
    Temperature Operating: 5° C to 45° C (41° F to 113° F)/Short term: 5° C to 55° C (23° F to 131° F)
    Nonoperating: -40° C to 70° C (-40° F to 158° F)
    Humidity Operating: 5% to 85% relative humidity noncondensing, but not to exceed 0.024kg water/kg dry air (0.053 lbs. water 2.205 lb. dry air)
    Short term: 5% to 90% relative humidity noncondensing, but not to exceed 0.024kg water/kg dry air (0.053 lbs. water 2.205 lb. dry air)
    Nonoperating: up to 93% relative humidity noncondensing, 40° C (104° F) max wet bulb
    Altitude Operating: 0m to 3,000m (0ft to 9840ft.) Maximum ambient temperature is derated by 1 degree C above 900 m, except in China where regulations may limit installations to a maximum altitude of 2,000 m.
    Acoustic noise Operating/Idling Acoustic Noise less than 7.2B @ 25° C (LwAd, 1B=10dB)
    Regulations
    Meets or exceeds the following requirements:
    Safety UL 60950-1, EN60950-1, IEC60950-1 CB scheme with all country differences
    Emissions FCC CFR 47 Part 15, ICES-003, EN55024, EN61000-3-2 and EN61000-3-3, EN300-386
    EMC (Immunity) EM55024
    Certifications
    • North America Safety (NRTL)
    • European Union (EU)
    • International CB Scheme
    • BIS (India)
    • BSMI (Taiwan)
    • RCM (Australia)
    • CCC (PRC)
    • MSIP (Korea)
    • VCCI (Japan)
    • EAC (Russia)
    European Union Directives
    • 2006/95/EC Low Voltage Directive
    • 2004/108/EC EMC Directive
    • 2011/65/EU RoHS Directive
    • 2012/19/EU WEEE Directive
    Dimensions and Weight
    Height 87.1 mm (3.43 in.) 2 RU
    Width 445 mm (17.52 in.) including mounting ears and without bezel 425.4 mm (16.75 in.)./td>
    Depth maximum with PSU's: 640.0 mm (25.2 in.)
    maximum w/o PSU's: 609.45 mm (24 in.)
    Weight Approximate (fully populated)
    17.5 kg (38.5 lb.)
    Rack Mounting
    Rack Units
    2
    Rack Kits Available
    • 19" 4-Post Rackmount Brackets
    • New Netra Chassis is 24" deep, 2U high
    • Sun Rack 1242 support
    • Sun Rack 1042 support
    1 The slide kit includes hardware that enables mounting to any of the following types of rack rails:
    • 6 mm threaded holes
    • #10-32 threaded holes
    • #10 threaded holes
    These must be compliant racks which have mounting depths of 27-30 inches.

      Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
     Feedback