Processor |
Number |
4 15-Core |
Architecture |
Intel Xeon E7 Processor Series |
CPUs |
Intel 2.80GHz 15-Core Xeon E7-8895 v2, 155W
|
Cache memory |
256KB unified (data and instruction) Level 2 cache
Up to 37.5 MB shared last Level 3 cache.
|
Main
Memory |
Capacities |
DIMM slots: 96 DIMM slots, 24 DIMMs per CPU
DIMM type: Registered low-voltage DDR3L-1600 DIMMs,
Registered low-voltage DDR3L-1600 Load Reduced DIMMs
DIMM size: 16GB and 32GB
Maximum capacity: 3TB |
Standard
Integrated Interfaces |
Network |
Four 10 GbE on-board Ethernet copper ports |
Network Management |
One dedicated 10/100/1000Base-T Ethernet copper management port |
Serial Management |
One TIA/EIA-232-F asynchronous RJ45 serial port |
USB |
Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports
Internal: 1 USB 2.0 Port |
PCI Express |
11 PCI Express 3.0 Slots
- 9 slots ae x8 PCI-E slots
- 2 slots are x16 PCI-E slots
|
Video |
One Rear and One Front HD15 VGA port |
Graphics controller |
VGA 2D graphics controller embedded.
Support remote console at a resolution up to 1600x1200x16bits@60Hz
(1024x678 when viewed remotely via ILOM RKVMS)
|
Internal
Mass Storage |
Disks |
Six 2.5" SAS front-accessible, hot-swappable disk bays.
Drive Type
|
Density
|
Speed
|
Form Factor
|
SAS
|
900GB
|
10,000 RPM
|
2.5"
|
SAS-2
|
1.6TB
|
Solid State
|
2.5"
|
|
Power
Supplies |
Dual redundant, hot swappable power supplies
2000W Capacity (From 200 Volts to 240 Volts)
|
Environment |
Power Consumption |
Online power calculator |
AC power |
100-127 VAC/200-240 VAC (50-60Hz) |
Maximum Input Current |
12A @ 100VAC / 12A @ 200VAC |
Maximum Power Consumption |
1800W |
Maximum Heat Output |
6143 BTU/hr |
Temperature |
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 68° C (-40° F to 154°
F) |
Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing
Nonoperating: up to 93% relative humidity noncondensing |
Altitude |
Single, non-rack system:
Operating: Up to 3048 m (10,000 ft.), maximum operating temperature
is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft).
Nonoperating: Up to 12,000 m (39,370 ft.) |
Acoustic Noise Emissions |
LwAd (1B= 10dB) at max ambient: 8.9 B (idle and operating room temperature)
LpAm bystander at max ambient: 75 dBA |
Regulations
Meets or exceeds the following requirements: |
Safety |
IEC 60950, UL/CSA60950, EN60950, CB scheme with all country differences |
RFI/EMI |
FCC CFR 47 Part 15 Class A, EN55022 Class A, EN300-386, EN 61000-3-2, EN 61000-3-3 |
Immunity |
EN 55024 ,EN 300 386 |
Certifications |
Safety: UL/cUL, UL DEMKO, CCC, CE, BSMI, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
Other: Labeled per WEEE (Waste Electrical and Electronic Equipment)
Directive (2002/96/EC) and RoHS Directive (2002/95/EC) |
Dimensions
and Weight (Sun Server X4-4) |
Height |
129.9 mm (5.1 in.) |
Width |
436.5 mm (17.2 in.) |
Depth |
732 mm (28.8 in.) |
Weight |
Maximum: 40 kg (88 lb.) |
Rack
Mounting |
Oracle ZFS Storage ZS4-4 Racks |
Racks are as follows:
- Sun Rack II 1242
- Sun Rack II 1042
|