Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Oracle ZFS Storage ZS3-ES: Hardware Specifications

Processor
Number Two 8-Core
Architecture Type: Intel Xeon E5-2600 family
CPUs Intel 2.1GHz 8-Core Xeon E5-2658 (10MB, 95W)
Cache L1: 32KB Instruction and 32KB data L1 cache per core
L2: 256KB shred data and instruction L2 cache per core
L3: Up to 20MB shared inclusive L3 cache per processor
Main Memory
Capacities Total DIMM slots: 16
DIMM type: DDR3 1600MHz Registered DIMMs
DIMM size: 16GB 1600MHz
Maximum capacity: 256GB
Standard Integrated Interfaces
Network Supports Four 100/1000/10000 Base-T Ethernet Ports (100 at full-duplex only)
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated RJ45 port
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: Two USB 2.0 ports
PCI Expansion Slots

Four low profile PCI Express 3.0 slots;
Slot 1: x16 mechanical / x16 electrical
Slot 2: x16 mechanical / x8 electrical
Slot 3: x8 mechanical / x8 electrical
Slot 4: Internal only access, dedicated to SAS controller for internal storage.

Internal Mass Storage
Disks 2 x 900GB 10,000 RPM HDD's in disk slots 0 and 1
2 x 1.6TB SSD's in disk slots 2 and 3 (Readzilla's)
Note: Remaining disk slots are filled with disk slot filler panels.
Attached Storage
Option #1
DE2-24P - Four SAS SSD's disk slots 20-23 (Logzilla's) and twenty 900GB 2.5" 10K RPM SAS HDD's (disk slots 0-19).
Option #2
DE2-24C - Four SAS SSD's disk slots 20-23 (Logzilla's) and twenty 4TB 3.5in 7200K RPM SAS HDD's (disk slots 0-19).
Power Supplies
Dual redundant, hot swappable power supplies
(Power supply rating output = 600W)
Environment
Voltage 100 to 127 / 200 to 240 VAC (90 to 132/180 to 264 VAC ranges)
Input Current 7.2 A @ 100 VAC (720 VA) Max
AC power 50-60 Hz (47 to 63 Hz range)
Temperature Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Maximum ambient operating temperature is derated by 1 degree C per 300 meters of elevation beyond 900 meters, up to a maximum altitude of 3,000 meters of elevation.)
Humidity Operating: 10% to 90% relative humidity noncondensing, short term -5 ° C to 55° C (25° F to 113° F) ;
5% to 90% noncondensing, but not to exceed 0.024 kg of water per kg of dry air (0.053 lbs water / 2.205 lbs dry air)
Nonoperating: up to 93% relative humidity noncondensing, 37.7° C (100.4° F) max wet bulb
Altitude Operating: up to 3000 m (9,840 ft.) at 35° C (95° F)
Nonoperating: Maximum 12,000 m (39,370 ft)
Acoustic 7.91 Bels A weighted operating; 5.28 Bels A weighted idling
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA-60950-1, 2nd Edition, 2007-03-27 ; EN60950-1:2006 +A11:2009 +A1:2010 +A12:2011 ; IEC60950-1:2005 +A1:2009CB Scheme with all country deviations ; CNS14336-1 ; GB4943
EMI EN55022:2006 +A1:2007/CISPR22:2008 Class A ; 47 CFR 15B Class A ; ICES-003 Class A ; VCCI Class A ; AS/NZ 3548 Class A ; CNS 13438 Class A ; KSC 5858 Class A ; GB9254 Class A ; EN61000-3-2 ; GB17625.1 ; EN61000-3-3
Immunity EN55024:2010 ; IEC 61000-4-2 Electrostatic discharge ; IEC 61000-4-3 RF E-field immunity ; IEC 61000-4-4 Electrical Fast Transient/Burst ; IEC 61000-4-5 Surge ; IEC 61000-4-6 RF-Conducted immunity ; IEC 61000-4-8 Power frequency magnetic field immunity ; IEC 61000-4-11 Voltage dips, short interruptions
Ergonomics EK1-1TB-2000
Dimensions and Weight (Sun Server X3-2)
Height 42.6 mm (1.7 in)
Width With Bezel: 482.4 mm (18.9 in)
Server Chassis: 436.5 mm (17.185 in)
Depth 737 mm (29 in) Max
Weight 24.3 kg (53.4 lbs)
Clearance and Service Access
Front
Rear
91 cm (36 in)
91 cm (36 in)
Rack Mounting
Oracle ZFS Storage ZS3-ES Racks Racks are as follows:
  • Sun Rack II 1042
  • Sun Rack II 1242

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.