Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Oracle ZFS Storage ZS3-BA: Hardware Specifications

Processor
Number 4 8-Core
Architecture Intel Xeon E7 Processor Series
CPUs Intel 2.0GHz 8-Core Xeon E7-4820, 105W
Cache memory 256KB unified (data and instruction) Level 2 cache
18MB or 30MB shared inclusive Level 3 cache
Main Memory
Capacities DIMM slots: 64 DIMM slots total, only 32 DIMM slots being used, DIMMs slots populated: 0,2,4,6
DIMM type: Registered DDR3-1333/PC3-10600 ECC DIMMs
DIMM size: 16GB
Maximum capacity: 512GB
Standard Integrated Interfaces
Network Four Integrated 10/100/1000 Base-T Gigabit Ethernet
Network Management One 10/100 Base-T Ethernet management port
Serial Management One TIA/EIA-232-F asynchronous RJ45 serial port
USB Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports
Internal: 1 USB 2.0 Port
PCI Express 10 PCI Express 2.0 Slots
  • 2 slots (3 and 5) are either x8 or x16 electrical interface (x16 connector)
  • 6 slots are x8 PCI-E slots
  • 2 slots are x4 PCI-E slots
Note: Slots 3 and 5 operate as x16 interfaces only when an x16 capable card is
installed and the adjacent slot (4 or 6) is unpopulated.
Video One Rear and One Front HD15 VGA port
Internal Mass Storage
Disks Two boot disks in the Sun Server X2-4 & 24 hot-swappable disks in the Oracle DE2-24C

Drive Type
Density
Speed
Form Factor
Supported In
SAS
4TB
7,200 RPM
3.5"
DE2-24C
SAS
900GB
10,000 RPM
2.5"
Sun Server X2-4 (boot disk)
SAS SSD (Solid State Drive)
73GB
NA
3.5"
DE2-24C (Logzilla)
SAS SSD (Solid State Drive)
1.6TB
NA
2.5"
Sun Server X2-4 (Readzilla)

Power Supplies
Dual redundant, hot swappable power supplies
2000W Capacity (From 200 Volts to 240 Volts)
Environment
AC power 100-127 VAC/200-240 VAC (50-60Hz)
Maximum Input Current 12A @ 100VAC / 12A @ 200VAC
Maximum Power Consumption 1800W
Maximum Heat Output 6143 BTU/hr
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 68° C (-40° F to 154° F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing
Nonoperating: up to 93% relative humidity noncondensing
Altitude Single, non-rack system:
Operating: Up to 3048 m (10,000 ft.), maximum operating temperature is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft).
Nonoperating: Up to 12,000 m (39,370 ft.)
Acoustic Noise Emissions LwAd (1B= 10dB) at max ambient: 8.9 B (idle and operating room temperature)
LpAm bystander at max ambient: 75 dBA
Regulations
Meets or exceeds the following requirements:
Safety IEC 60950, UL/CSA60950, EN60950, CB scheme with all country differences
RFI/EMI FCC CFR 47 Part 15 Class A, EN55022 Class A, EN300-386, EN 61000-3-2, EN 61000-3-3
Immunity EN 55024 ,EN 300 386
Certifications Safety: UL/cUL, UL DEMKO, CCC, CE, BSMI, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
Other: Labeled per WEEE (Waste Electrical and Electronic Equipment) Directive (2002/96/EC) and RoHS Directive (2002/95/EC)
Dimensions and Weight (Sun Server X2-4)
Height 129.85 mm (5.1 in.)
Width 436.5 mm (17.2 in.)
Depth 732 mm (28.8 in.)
Weight Maximum: 38.5 kg (85 lb.)
Minimum: 29.5 kg (65 lb.)
Rack Mounting
Oracle ZFS Storage ZS3-BA Racks Racks are as follows:
  • Sun Rack II 1242
  • Sun Rack II 1042

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.