Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Zero Data Loss Recovery Appliance X6: Hardware Specifications

Processor
Number Two ( per X6-2 Server), Two ( per X6-2L Server)
Architecture Type: Intel Xeon E5-2699 v4 Processor Series (X6-2), Intel Xeon E5-2630 Processor Series (X6-2L)
CPUs Intel 2.20GHz 22-Core Xeon E5-2699 v4, 145W (X6-2), Intel 2.20GHz 10-Core Xeon E5-2630 v4, 85W (X6-2L)
Hardware
X6-2 Capacities
  • Two Oracle Server X6-2 Compute Servers
  • 256GB DDR4 Memory
  • 3 x 100-10GbE Ethernet Ports (Copper)
  • Sun Dual 10 Gb Ethernet SFP+ PCIe 2.0 Low Profile Adapter
  • 2 x QDR (40Gb/s) InfiniBand Ports
  • Oracle Integrated Lights Out Manager (ILOM)
  • 2 x Redundant Hot-Swappable Power Supplies
  • Redundant Hot-Swappable Fans
  • Disk Controller HBA with 1GB Supercap-backed Write Cache
X6-2L Capacities
  • Three (Base Rack) Oracle Server X6-2L Storage Servers
  • 12 x 8TB 7,200 RPM High Capacity disks
  • Between 2x and 4x PCI flash cards for caching metadata and other functions
  • Oracle Integrated Lights Out Manager (ILOM)
  • 2 x Redundant Hot-Swappable Power Supplies
  • 2 x QDR (40Gb/s) InfiniBand Ports
  • Redundant Hot-Swappable Fans
  • Disk Controller HBA with 1GB Supercap-backed Write Cache
Additional Hardware Components
  • Two 36 port QDR (40 Gb/sec) Infiniband Switches
  • 42U Rack
  • Ethernet switch for administrative connectivity to servers
  • Two Redundant Power Distribution Units (PDU's)

  • Included Spare Parts Kit Contains:
  • One 8TB 7,200 RPM High Capacity Disk Drive
  • One PCI flash card
Included Software
Oracle Server X6-2(L) Servers Zero Data Loss Recovery Software version 12.1.2.3.0

Oracle Database 12c Release 1 (12.1.0.2) Patch Set 1
Environmentals (Base Rack)
Maximum power usage 4.0 kW (4.1 kVA)
Typical power usage 2.8 kW (2.9kVA)
Cooling maximum usage 13,679 BTU/hour (14,432 kj/hour)
Cooling at typical usage 9,575 BTU/hour (10,102 kj/hour)
Airflow at maximum usage 633CFM
Airflow at typical usage 433 CFM
Acoustic Noise Operating 8.3B
Dimensions and Weight
Height 1998 mm (78.66 in.)
Width 600 mm (23.62 in.)
Depth 1200 mm (47.24 in.)
Weight 875.7 kgs (1930.5 lbs.) Full Rack
381.2 kgs (840.5 lbs.) Base Rack

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.