Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Zero Data Loss Recovery Appliance X4: Hardware Specifications

Processor
Number Two ( per X4-2 Server), Two ( per X4-2L Server)
Architecture Type: Intel Xeon E5-2697 v2 Processor Series (X4-2), Intel Xeon E5-2630 Processor Series (X4-2L)
CPUs Intel 2.70GHz 12-Core Xeon E5-2697 v2, 130W (X4-2), Intel 2.60GHz 6-Core Xeon E5-2630 v2, 80W (X4-2L)
Hardware
X4-2 Capacities
  • Two Sun Server X4-2 Compute Servers
  • 256GB Memory
  • 3 x 1/10 Gb Ethernet Ports (Copper)
  • Sun Dual 10 Gb Ethernet SFP+ PCIe 2.0 Low Profile Adapter
  • Sun Storage Dual 16 Gb Fibre Channel PCIe Universal HBA, QLogic for tape connectivity (Optional)
  • 2 x QDR (40Gb/s) InfiniBand Ports
  • Oracle Integrated Lights Out Manager (ILOM)
  • 2 x Redundant Hot-Swappable Power Supplies
  • Redundant Hot-Swappable Fans
X4-2L Capacities
  • Three (Base Config) or Fourteen (Full Rack) Sun Server X4-2L Storage Servers
  • 12 x 4TB (raw) 7,200 RPM High Capacity disks
  • Between 2x and 4x PCI flash cards for caching metadata and other functions
  • Oracle Integrated Lights Out Manager (ILOM)
  • 2 x Redundant Hot-Swappable Power Supplies
  • 2 x QDR (40Gb/s) InfiniBand Ports
  • Redundant Hot-Swappable Fans
Additional Hardware Components
  • Two 36 port QDR (40 Gb/sec) Infiniband Switches
  • 42U Rack
  • Ethernet switch for administrative connectivity to servers
  • Two Redundant Power Distribution Units (PDU's)

  • Included Spare Parts Kit Contains:
  • One 4TB 7,200 RPM High Capacity Disk Drive
  • One PCI flash card
Included Software
Sun Server X4-2(L) Servers Zero Data Loss Recovery Software version 12.1.1.1.1

Oracle Database 12c Release 1 (12.1.0.2) Patch Set 1
Environmentals (Full Rack)
Maximum power usage 8.0 kW (8.1 kVA)
Typical power usage 5.6 kW (5.7 kVA)
Cooling maximum usage 27,200 BTU/hour (28,700 kj/hour)
Cooling at typical usage 19,000 BTU/hour (20,100 kj/hour)
Airflow at maximum usage 1,260 CFM
Airflow at typical usage 880 CFM
Dimensions and Weight
Height 1998 mm (78.66 in.)
Width 600 mm (23.62 in.)
Depth 1200 mm (47.24 in.)
Weight 724.9 kgs (1598 lbs.) Full Rack
393.3 kgs (867 lbs.) Base Rack

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.