Sun Server X4-8: Hardware Specifications

Processor
Number 4 or 8 CMODs (Compute Modules), providing 4 or 8 CPU configurations
Architecture Type: Intel Xeon E7-8895 Processor Series
CPUs Intel 2.80GHz 15-Core Xeon E7-8895 v2, 155W
Main Memory
Capacities
  • DIMM Slots per CMOD: 24.
  • Total DIMM Slots in 4 CMOD Configuration: 96
  • Total DIMM Slots in 8 CMOD Configuration: 192
  • DIMM Size and Type: 16GB: DDR3-1600 GHz ECC registered or 32GB: DDR3-1600 GHz load-reduced ECC DIMMs (LRDIMM)
  • Minimum Populated DIMM Slots per CMOD : 4 DIMMs per CMOD
  • Minimum Memory Capacity in 4 CMOD Configuration: 256GB using 16GB DIMMs or 512GB using 32GB DIMMs
  • Minimum Memory Capacity in 8 CMOD Configuration: 512GB using 16GB DIMMs or 1TB using 32GB DIMMs
  • Maximum Memory Capacity in 4 CMOD Configuration: 1.5TB using 32GB DIMMs or 3TB using 32GB DIMMs
  • Maximum Memory Capacity in 8 CMOD Configuration: 3TB using 16GB DIMMs or 6TB using 32GB DIMMs
Standard I/O
Network Two 1 GbE network ports (RJ-45 connector)
Network Management One 10/100/1000Base-T Ethernet Service Processor (SP) (RJ-45 connector) port
Serial Management One RS-232 RJ45 serial console port
USB Rear: 2 USB 2.0 Ports
Internal: 2 USB 2.0 Ports
Video One VGA 1,280 x1,024x8 MB @ 60 Hz graphics controller port with DB-15 connector
I/O Expansion 2 PCI Express 3.0 Slots per CMOD for maximum of 16 Slots. Hot swappable via Dual PCIe Card Carrier (DPCC).
  • 1 x8 PCI-E slot
  • 1 x16 PCI-E slot
Internal Mass Storage
Disks Eight rear-accessible and hot-swappable 2.5" SAS-2 HDDs or eight 2.5" SATA-3 SSDs for up to 9.6TB of internal storage.

Drive Type
Density
Speed
Form Factor
SAS-2
600GB
10,000 RPM
2.5"
SAS-2
1.2TB
10,000 RPM
2.5"
SATA-3
400GB
Solid State
2.5"

Power Supplies and Fans
  • Four dual redundant, hot swap power supplies and 8 Hot-swap Redundant Dual Fans.
  • Cooling is front to back.
Environment
Power Consumption Online power calculator
AC power Nominal input frequencies 50/60 Hz
Operating input voltage range 200-240 VAC
Rated input current 23A@200 to 230 VAC 12A max per cord
Maximum power consumption 3400W
Temperature Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158°F)
Humidity Operating: 10% to 90% relative humidity noncondensing
Altitude Single, non-rack system:
Operating: Up to 3048 m (10,000 ft.), maximum operating temperature is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft).
Nonoperating: Up to 12,000 m (39,370 ft.)
Acoustic Noise Emissions LwAd (1B= 10dB) at max ambient: 8.9 B (idle and operating room temperature)
LpAm bystander at max ambient: 75 dBA
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA 60950-1, EN 60950-1, IEC 60950-1 (CB Scheme with all country differences), North America (NRTL), European Union (EU), International CB Scheme, 2006/95/EC (73/23/EEC) Low Voltage Directive
EMC EN 55022, CNS-13438 Class A (Taiwan), FCC CFR 47 CFR 15B Class A (Code of Federal Regulations, Title 47, Part 15, Subpart B Class A (United States), ICES-003 (A) NMB-3 (A) Class A (Canada), ETSI EN300386 (V1.6.1), VCCI: 2008 Class A (Japan), KN 22 RRL Public Notice 2009-9 (Dec 21, 2009)
Immunity EN55024 (Immunity), EN61000-3-2, EN61000-3-3
Other Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC, Low Voltage Directive 2006/95/EC, and EMC Directive 2004/108/EC
Certifications
Safety Marks UL
Regulatory Marks CE, FCC, EAC, C-Tick, VCCI, BSMI, KCC, ICES-003 (A), NMB-3 (A), WEEE symbol, China RoHS symbol
Operating Altitude m to 3,000 m (0 ft to 9,840 ft) maximum ambient temperature is derated by one degree C per 300 m above 900 m, except in China where regulations may limit installations to a maximum altitude of 2,000 m.
Nonoperating Altitude 0 m to 12,000 m (0 ft to 40,000 ft)
Dimensions and Weight
Height 219.25 mm (8.63 in.)
Width 445 mm (17.5 in.)
Depth 834 mm (32.8 in.)
Weight Maximum: 114 kg (250 lbs.)
Rack Mounting
Sun Server X4-8 Racks
  • Tooless Slide Rail Rackmount Kit
  • Sun Rack 1242
  • Sun Rack 1042

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.