Processor
Number 2 or 4 15-Core
Architecture Type: Intel Xeon E7-8895 Processor Series
CPUs Intel 2.80GHz 15-Core Xeon E7-8895 v2, 155W
Cache memory 256KB unified (data and instruction) Level 2 cache
Up to 37.5 MB shared last Level 3 cache.
Main Memory
Capacities DIMM slots: 96 DIMM slots, 24 DIMMs per CPU
DIMM type: Registered low-voltage DDR3L-1600 DIMMs,
Registered low-voltage DDR3L-1600 Load Reduced DIMMs
DIMM size: 8GB, 16GB, 32GB (LR)
Maximum capacity: 3TB
Standard Integrated Interfaces
Network Four 10 GbE on-board Ethernet copper ports
Network Management One dedicated 10/100/1000Base-T Ethernet copper management port
Serial Management One RS-232 RJ45 serial port
USB Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports
Internal: 1 USB 2.0 Port
PCI Express 11 PCI Express 3.0 Slots
  • 9 slots are x8 PCI-E slots
  • 2 slots are x16 PCI-E slots
Note: Slot 2 is designated for the storage controller HBA.
Video One Rear and One Front HD15 VGA port
Graphics controller VGA 2D graphics controller embedded.
Support remote console at a resolution up to 1600x1200x16bits@60Hz
(1024x678 when viewed remotely via ILOM RKVMS)
Internal Mass Storage
Disks Six 2.5" SAS-2/SATA-3 front-accessible, hot-swappable disk bays.

Drive Type
Density
Speed
Form Factor
SAS-2
600GB
10,000 RPM
2.5"
SAS-2
1.2TB
10,000 RPM
2.5"
SATA-3
400GB
Solid State
2.5"

Power Supplies
Dual redundant, hot swappable power supplies
2000W Capacity (From 200 Volts to 240 Volts)
Environment
Power Consumption Online power calculator
AC power 100-127 VAC for 2 CPU's
200-240 VAC for 2 or 4 CPU's
50/60 Hz Nominal frequencies
Maximum Input Current 12A @ 100VAC / 12A @ 200VAC
Maximum Power Consumption 1467W
Maximum Heat Output 5005 BTU/hr
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 68° C (-40° F to 154°F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing
Nonoperating: up to 93% relative humidity noncondensing
Altitude Single, non-rack system:
Operating: Up to 3048 m (10,000 ft.), maximum operating temperature is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft).
Nonoperating: Up to 12,000 m (39,370 ft.)
Acoustic Noise Emissions LwAd (1B= 10dB) at max ambient: 8.9 B (idle and operating room temperature)
LpAm bystander at max ambient: 75 dBA
Regulations
Meets or exceeds the following requirements:
Safety IEC 60950, UL/CSA60950-1, EN60950-1, IEC60950-1 (CB scheme with all country differences), North America (NRTL), European Union (EU), International CB Scheme, 2006/95/EC (73/23/EEC) Low Voltage Directive
EMC FCC CFR 47 Part 15B Class A, EN55022 Class A, CNS-13438 Class A (Taiwan), Title 47, Part 15, Subpart B Class A (United States), ICES-003 (A) NMB-3 (A) Class A (Canada), ETSI EN300386 (V1.6.1), VCCI: 2008 Class A (Japan), KN 22 RRL Public Notice 2009-9 (Dec 21, 2009)
Immunity EN 55024 (Immunity), EN61000-3-2, EN61000-3-3
Certifications Safety Marks: UL/cUL, UL DEMKO, CCC, CE, BSMI, GOST-R, S-Mark
Regulatory: CE, FCC, EAC, C-Tick, VCCI, BSMI, KCC, ICES-003(A), NMB-3(A), WEEE symbol, China RoHS symbol
Dimensions and Weight
Height 129.9 mm (5.1 in.)
Width 436.5 mm (17.2 in.)
Depth 732 mm (28.8 in.)
Weight Maximum: 40 kg (88 lb.)
Rack Mounting
Sun Server X4-4 Racks
( Using the Tooless Slide Rail Rackmount Kit PN#371-4791 )
Racks are as follows:
  • Sun Rack 1242
  • Sun Rack 1042

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.