Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Server X4-2L:Hardware Specifications

Processor
Number One or Two: (See Single CPU Configuration Restrictions below)
Architecture Type: Intel Xeon E5-2600 v2 family
CPUs Intel 2.5GHz Quad-Core Xeon E5-2609 v2 (80W)
Intel 2.6GHz 6-Core Xeon E5-2630 v2 (80W)
Intel 2.6GHz 8-Core Xeon E5-2650 v2(95W)
Intel 3.0GHz 10-Core Xeon E5-2690 v2 (130W)
Intel 2.7GHz 12-Core Xeon E5-2697 v2 (130W)
Cache L1: 32KB Instruction and 32KB data L1 cache per core
L2: 256KB shred data and instruction L2 cache per core
L3: Up to 30MB shared inclusive L3 cache per processor
Single CPU Configuration Restrictions
  • only two out of four onboard Ethernet ports are supported
  • up to 8 DIMMs are supported
  • up to 3 out of 6 PCIe slots are supported
Main Memory
Capacities Total DIMM slots: 16 (8 DIMMs/CPU)
DIMM type: DDR3 1600MHz Registered DIMMs
DIMM size: 8GB 1600MHz, 16GB 1600MHz, or 32GB 1600MHz
Maximum capacity: 512GB (when configured with 32GB DIMMs)
Standard Integrated Interfaces
Network Supports Four 100/1000/10000 Base-T Ethernet Ports (100 at full-duplex only)
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated RJ45 port
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: Two USB 2.0 ports
PCI Expansion Slots

Six low profile PCI Express 3.0 slots;
Slot 1: x16 electrical / x16 mechanical
Slots 2-6: x8 electrical

Internal Mass Storage
Disks and Flash Three Disk Backplanes configurations
  • 8-Disk configuration with DVD: 2.5in 300GB / 600GB SAS-2 SSD
  • 12-Disk configuration: 3.5in 1.2TB SAS-2 or 4TB SAS(2 additional 2.5" disk slots in the rear)
  • 24-Disk configuration: 2.5in 300GB / 600GB SAS-2 (2 additional 2.5" disk slots in the rear)
  • Internal 4GB USB 2.0 Flash Drive
Uses one of two supported internal HBAs for internal storage. The HBA is to be installed in PCI Express Slot 6.
Power Supplies
Dual redundant, hot swappable power supplies
(Maximum output power = 1000W)
Environment
Power Consumption Online power calculator
Voltage 100 to 127 / 200 to 240 VAC
Input Current 12.0 A-8.5 A @ 100-127 V
5.7 A @ 200-240 V
AC power 50-60 Hz (47 to 63 Hz range)
Temperature Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Humidity Operating: 10% to 90% relative humidity noncondensing,
Nonoperating: up to 93% relative humidity noncondensing
Altitude Operating:Up to 9,840 feet (3,000 m*) maximum ambient temperature is derated by 1° C per 300 m above 900 m
(*except in China where regulations may limit installations to a maximum altitude of 6,560 feet or 2,000 m)
Nonoperating: Maximum 12,000 m (39,370 ft)
Acoustic 7.61 Bels A weighted operating; 5.65 Bels A weighted idling
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA-60950-1, 2nd Edition, EN60950-1-2006 + A11:2009 + A1:2010 + A12:2011, IEC60950-1:2005 + A1:2009 CB scheme
with all country deviations, CNSI4336-1, GB4943.1-2012
EMI EN55022:2010 , CISPR22:2008 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZS CISPR 22:2009/A1:2010 Class A,
CNS 13438 Class A, GB9254 Class A, EN61000-3-2, GB17625.1, EN61000-3-3
Immunity EN 55024:2010
Certifications Safety: UL/cUL Listing, CE, BSMI, GOST R, CCC
EMC: CCC, CE, FCC, VCCI, ICES, C-Tick, KCC, GOST R, BSMI, Class A
Other: Complies with WEEE Directive (2012/19/EC), RoHS Directive (2011/65/EC)
Dimensions and Weight
Height 87.6 mm (3.5 in)
Width 445.0 mm (17.5 in)
Depth 737 mm (29 in)
Weight 28.5 kg (63 lbs) fully populated
Clearance and Service Access
Front
Rear
Top
123.2 cm (48.5 in)
91.4 cm (36 in)
91.4 cm (36 in)

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
 Feedback