Processor |
Number |
One or Two: (See Single CPU Configuration Restrictions below) |
Architecture |
Type: Intel Xeon E5-2600 v2 family |
CPUs |
Intel 2.5GHz Quad-Core Xeon E5-2609 v2 (80W)
Intel 2.6GHz 6-Core Xeon E5-2630 v2 (80W)
Intel 2.6GHz 8-Core Xeon E5-2650 v2(95W)
Intel 3.0GHz 10-Core Xeon E5-2690 v2 (130W)
Intel 2.7GHz 12-Core Xeon E5-2697 v2 (130W) |
Cache |
L1: 32KB Instruction and 32KB data L1 cache per core
L2: 256KB shred data and instruction L2 cache per core
L3: Up to 30MB shared inclusive L3 cache per processor |
Single CPU Configuration Restrictions |
- only two out of four onboard Ethernet ports are supported
- up to 8 DIMMs are supported
- up to 3 out of 6 PCIe slots are supported
|
Main Memory |
Capacities |
Total DIMM slots: 16 (8 DIMMs/CPU)
DIMM type: DDR3 1600MHz Registered DIMMs
DIMM size: 8GB 1600MHz, 16GB 1600MHz, or 32GB 1600MHz
Maximum capacity: 512GB (when configured with 32GB DIMMs) |
Standard Integrated Interfaces
|
Network |
Supports Four 100/1000/10000 Base-T Ethernet Ports (100 at full-duplex only) |
Network Management |
One dedicated 10/100Base-T Ethernet port |
Serial Management |
One dedicated RJ45 port |
USB |
Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: Two USB 2.0 ports |
PCI Expansion Slots |
Six low profile PCI Express 3.0 slots;
Slot 1: x16 electrical / x16 mechanical
Slots 2-6: x8 electrical
|
Internal Mass Storage |
Disks and Flash |
Three Disk Backplanes configurations
- 8-Disk configuration with DVD: 2.5in 300GB / 600GB SAS-2 SSD
- 12-Disk configuration: 3.5in 1.2TB SAS-2 or 4TB SAS(2 additional 2.5" disk slots in the rear)
- 24-Disk configuration: 2.5in 300GB / 600GB SAS-2 (2 additional 2.5" disk slots in the rear)
- Internal 4GB USB 2.0 Flash Drive
|
Uses one of two supported internal HBAs for internal storage.
The HBA is to be installed in PCI Express Slot 6. |
Power Supplies |
Dual redundant, hot swappable power supplies
(Maximum output power = 1000W) |
Environment |
Power Consumption |
Online power calculator |
Voltage |
100 to 127 / 200 to 240 VAC |
Input Current |
12.0 A-8.5 A @ 100-127 V
5.7 A @ 200-240 V |
AC power |
50-60 Hz (47 to 63 Hz range) |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
|
Humidity |
Operating: 10% to 90% relative humidity noncondensing,
Nonoperating: up to 93% relative humidity noncondensing
|
Altitude |
Operating:Up to 9,840 feet (3,000 m*) maximum ambient temperature is derated by 1° C per 300 m above 900 m
(*except in China where regulations may limit installations to a maximum altitude of 6,560 feet or 2,000 m)
Nonoperating: Maximum 12,000 m (39,370 ft) |
Acoustic |
7.61 Bels A weighted operating; 5.65 Bels A weighted idling |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA-60950-1, 2nd Edition, EN60950-1-2006 + A11:2009 + A1:2010 + A12:2011, IEC60950-1:2005 + A1:2009 CB scheme
with all country deviations, CNSI4336-1, GB4943.1-2012 |
EMI |
EN55022:2010 , CISPR22:2008 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZS CISPR 22:2009/A1:2010 Class A,
CNS 13438 Class A, GB9254 Class A, EN61000-3-2, GB17625.1, EN61000-3-3
|
Immunity |
EN 55024:2010 |
Certifications |
Safety: UL/cUL Listing, CE, BSMI, GOST R, CCC
EMC: CCC, CE, FCC, VCCI, ICES, C-Tick, KCC, GOST R, BSMI, Class A
Other: Complies with WEEE Directive (2012/19/EC), RoHS Directive (2011/65/EC) |
Dimensions and Weight |
Height |
87.6 mm (3.5 in) |
Width |
445.0 mm (17.5 in) |
Depth |
737 mm (29 in) |
Weight |
28.5 kg (63 lbs) fully populated |
Clearance
and Service Access |
Front
Rear Top |
123.2 cm (48.5 in)
91.4 cm (36 in) 91.4 cm (36 in) |