Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Blade X6275 Server Module: Hardware Specifications

Note: Modular System (chassis) specifications are documented on the chassis specification page. Reference the Servers/Blade section of the Handbook's Systems List to find documentation on Modular Systems.
Processor
Number Two dual compute nodes. 2 CPUs/node, 8 cores/node, 16 cores/blade.
Architecture Type:Quad-core, Intel[TM] Xeon 5500 series processors provide Intel Quick Path Interconnect (QPI), Hyper-Threading (HT) and Intel Turbo Boost Technology.
  • Model/Speed: L5520, Quad-Core, 2.26 GHz, 60W
  • Model/Speed: E5520, Quad-Core, 2.26 GHz, 80W
  • Model/Speed: E5540, Quad-Core, 2.53 GHz, 80W
  • Model/Speed: X5560, Quad-Core, 2.80 GHz, 95W
  • Model/Speed: X5570, Quad-Core, 2.93 GHz, 95W
Cache Memory 8 MB, L3 Cache
Main Memory
Memory Type 1333 and 1066 MHz DDR3 Registered DIMMs
Capacities
  • Maximum memory: 96GB.
  • Total DIMM slots: 24 (12 per node).
  • DIMM sizes: 2GB, and 4GB.
Sun Flash Modules
  • Optional 24GB SATA-based Sun Flash Module provide storage acceleration and a boot source.
Management Environment
Sun Blade Server Module Service Processor (SP)
  • There are two SPs (1/node) on the SP mezzanine card.
  • The SPs run Integrated Lights-Out Manager (ILOM).
  • The SP card provides dedicated Management 10/100 Management Ethernet Port.
  • ILOM on the SP card can be accessed via a Dongle cable assembly's connection to the Universal Connector Port (UCP) on the front of the Sun Blade X6275. The Sun Blade X6275 server module support the (3-port) dongle cable (X-Option part number X4622A).
  • The SP card and ILOM provide the following:
    • A Browser User Interface for control of the system through a graphical interface.
    • Remote media management over ip with full Keyboard, Video, Mouse, and Storage (KVMS) redirection.
    • DMTF style CLI.
    • IPMI 2.0 compliance for management and control.
    • Compatibility for third-party SNMP system managers with requirements for SNMP (v1, v2C, v3).
    • Monitor and report system and component status on all Field Replaceable Units (FRUs).
Standard Integrated Interfaces
Universal Connector Port (UCP) There are two UCPs on the Sun Blade X6275 - 1/node. Available via the Dongle Cable Assembly (Option X4622A/3 cable) connection to the UCP, each UCP provides:
  • 2 USB 2.0 ports.
  • VGA graphics (DB-15 connector)
  • RJ-45 serial port for ILOM console.
Network Management
  • One 10/100Base-T Ethernet connection per node.
Ethernet
  • One 10/100/1000Base-T Ethernet port per node.
Midplane I/O per compute node
  • One (x8) PCI Express Gen 2 bus to the PCI ExpressModule (EM) slot.
  • One 10/100/1000Base-T Ethernet Interface using Intel 82567 GbE controller, interface to one NEM.
  • 10/100 Ethernet management port to the Chassis Monitoring Module (CMM). (Note:Shared between 2 compute nodes via on-board switch).
PCI Interfaces with the Sun Blade Modular System (chassis)
  • The Sun Blade X6275 has two PCI Express Gen 2 interfaces per server module (one per compute node), via passive mid-plane.
  • I/O is offered in two form factors:
    • PCI Express ExpressModules (EM)
      and
    • PCI Express Network Express Modules (NEM).
  • Each Sun Blade X6275 has four, PCI Express links allocated to:
    • Two EMs
      and
    • Two NEMs.
  • Each NEM has one link assigned to each server module. All server modules share the NEM. For example, Blade 0 has access to NEM 0/slot 0, and NEM 1/slot 0. Blade 1 to NEM 0/slot 1 and NEM 1/slot 1, etc.
  • EM slots are not shared between server modules. Each EM slot is specific to one server module.
Regulations
Dimensions and Weights
Height 44.0 mm (1.7 in).
Width 327.0 mm (12.87 in).
Depth 512.0 mm (20.16 in).
Weight (fully configured) 20.61 lbs.

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.