Processor |
| Number |
Two or Four SPARC M8 32-Core 5.0GHz processors; upgradeable from two to four processors |
| CPUs |
- 5.0GHz 32-Core
- Up to 256 threads per processor (up to 8 threads per core)
- Eight Data Analytics Accelerator units per processor, each supporting four concurrent in-memory analytics engines with decompression.
- Thirty-two on-chip encryption instruction accelerators (one per core) with direct non-privileged
support for
16 industry-standard cryptographic algorithms: AES, Camellia, CRC32c, DES, 3DES, 3DES, DH, DSA,
ECC,
MD5, RSA, SHA-1, SHA-224, SHA-256, SHA-3, SHA-384, SHA-512 (one per core)
|
| Cache memory |
Level 1: 32 KB instruction and 16 KB data per core
Level 2: 256 KB L2 I$ per four cores, 128 KB L2 D$ per core
Level 3: 64 MB L3$ on chip |
|
Main Memory |
| Capacities |
- Total DIMM slots:16 dual inline memory module (DIMM) slots per processor supporting half and fully populated memory configurations.
- DIMM type: DDR4-2400
- DIMM size: 32GB or 64GB
- Maximum Configuration (2 processor): 2TB (32 × 64GB)
- Maximum Configuration (4 processor): 4TB (64 × 64GB)
|
|
Standard Integrated Interfaces
|
| Network |
4 × 10 GbE (100 Mbps/1 Gbps/10 Gbps), full duplex only, auto-negotiating
|
| Network Management |
One dedicated 10/100Base-T RJ-45 port Ethernet port |
| Serial Management |
One dedicated RJ-45 port |
| Remote Management |
Onboard system processor, running Integrated Lights
Out Manager (ILOM) |
| Graphics |
Two VGA connector |
| USB |
Front: 2 Front USB 3.0 Ports
Rear: 2 Rear USB 3.0 Ports
|
| PCI Expansion Slots |
- 16 low-profile PCI-Express 3.0 slots.
| Slot # |
Physical |
Electrical |
| 1 |
x8 |
x8 |
| 2 |
x8 |
x8 |
| 3 |
x16 |
x16 |
| 4 |
x16 |
x16 |
| 5 |
x8 |
x8 |
| 6 |
x8 |
x8 |
| 7 |
x16 |
x16 |
| 8 |
x16 |
x16 |
| 9 |
x8 |
x8 |
| 10 |
x8 |
x8 |
| 11 |
x16 |
x16 |
| 12 |
x16 |
x16 |
| 13 |
x8 |
x8 |
| 14 |
x8 |
x8 |
| 15 |
x16 |
x16 |
| 16 |
x16 |
x16 |
|
|
Internal Mass Storage |
| Disks |
- Up to eight 2.5-inch SAS-3 drives
- 600GB or 1.2TB 2.5-inch SAS-3 disk drives
- Optional Internal Storage:
- 800GB Solid State Drives, maximum of eight (installed in standard drive bays)
- 6.4TB NVMe Drives, maximum of eight (installed in standard drive bays)
- RAID 0, RAID 1, and RAID 10 and 1E support
|
|
Power Supplies |
| 4 × 3000 Watt, hot-swappable, 2+2
redundant power supply units (PSU) |
|
Environment |
| Power Consumption |
Online power calculator |
| Input Voltage |
200 - 240 VAC, 50-60Hz |
| Input Current |
12.6 A @ 200 VAC (per cord)
|
| Input Power |
5040 W @ 200 VAC |
| Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)
Note: Above 900m (3000 ft), decrease in maximum temperature as altitude
increase, 1° C/300m (1.8° F/1000ft)
|
| Humidity |
Operating: 10% to 80% relative humidity noncondensing, 27°
C (81° F) maximum wet bulb
Nonoperating: 85% relative humidity noncondensing, 38° C (100°
F) maximum wet bulb |
| Altitude |
Operating: 0m to 3000m (9,840 ft.) at 40° C (95° F)
Nonoperating: 0m to 12000m (39,370 ft.) |
| Vibration |
Operating: 0.15 G (vertical), 0.10 G (horizontal), 5 to 500 Hz,
swept-sine
|
| Shock |
Operating: 3G, 11 ms, Half-sine
swept-sine
|
| Acoustic Noise |
Operating at 60%: 8.7 B (LwAd, 1B = 10dB)
Operating at 100%: 9.9 B (LwAd, 1B = 10dB)
Operating at 60%: 71.2 dBA - LpAm (energy average of four bystander positions)
Operating at 100%: 82.5 dBA - LpAm (energy average of four bystander positions) |
Regulations
Meets or exceeds the following requirements: |
| Safety |
UL/CSA-60950-1, EN60950-1 and IEC 60950-1 CB Scheme with all country deviations |
| Emissions |
FCC 47 CFR 15, ICES-003, EN55032, EN61000-3-2, and EN61000-3-3 |
| Immunity |
EN55024 |
| Certifications |
North American Safety (NRTL), European Union (EU), International CB Scheme, BIS (India),
BSMI (Taiwan), RCM (Australia), MSIP (Korea), VCCI (Japan) |
| European Union Directives |
Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU,
Low Voltage Directive, 2014/35/EU, EMC Directive, 2014/30/EU, and (WEEE) 2012/19/EU
|
|
Dimensions and Weight |
| Rack Units |
6U |
| Height |
266.7 mm (10.5 in.) |
| Width |
445 mm (17.5 in.) |
| Depth |
835 mm (32.9 in.) |
| Weight |
Appx 98.66 kg (217.5 lbs), without rackmount kit |
| Clearance
and Service Access |
| Front |
914.4 mm (36 in.) |
| Rear |
914.4 mm (36 in.) |
| Airflow (front) |
50.8 mm (2 in.) |
| Airflow (rear) |
76.2 mm (3 in.) |