Processor |
Number |
One SPARC M8 32-Core 5.0GHz processor |
CPUs |
- 5.0GHz 32-Core
- 256 threads per processor (up to 8 threads per core)
- Eight Data Analytics Accelerator units per processor, each supporting four concurrent in-memory analytics engines with decompression.
- Thirty-two on-chip encryption instruction accelerators with direct non-privileged
support for
16 industry-standard cryptographic algorithms: AES, Camellia, CRC32c, 3DES, 3DES, DH, DSA,
ECC,
MD5, RSA, SHA-1, SHA-224, SHA-256, SHA-384, SHA-512 (one per core)
|
Cache memory |
Level 1: 32 KB instruction and 16 KB data per core
Level 2: 256 KB L2 I$ per four cores, 128 KB L2 D$ per core
Level 3: 64 MB L3$ on chip |
Main Memory |
Capacities |
- Total DIMM slots: 16 dual inline memory module (DIMM) slots per processor supporting half and fully populated memory configurations.
- DIMM type: DDR4-2400
- DIMM size: 16GB, 32GB or 64GB
- Maximum capacity: 1TB (16 × 64GB)
|
Standard Integrated Interfaces
|
Network |
4 × 10 GbE (100 Mbps/1 Gbps/10 Gbps), full duplex only, auto-negotiating
|
Network Management |
One dedicated 10/100Base-T RJ-45 port Ethernet port |
Serial Management |
One dedicated RJ-45 port |
Remote Management |
Onboard system processor, running Integrated Lights
Out Manager (ILOM) |
Graphics |
One DB-15 VGA connector |
USB |
Front: 2 USB 2.0 Ports
Rear: 2 USB 3.0 Ports
|
PCI Expansion Slots |
- 6 low-profile PCI-Express 3.0 slots.
Slot # |
Physical |
Electrical |
1 |
x8 |
x8 |
2 |
x8 |
x8 or unused if slot 3 x16 |
3 |
x16 |
x8 or x16 |
4 |
x16 |
x8 or x16 |
5 |
x8 |
x8 or unused if slot 4 x16 |
6 |
x8 |
x8 |
|
Internal Mass Storage |
Disks |
- Up to eight 2.5-inch SAS-3 drives
- 600GB or 1.2TB 2.5-inch SAS-3 disk drives
- Optional Internal Storage:
- 800GB Solid State Drives, maximum of eight (installed in standard drive bays)
- 6.4TB NVMe Drives, maximum of four (installed in standard drive bays)
- RAID 0, RAID 1, and RAID 1E/10 support
|
Power Supplies |
2 × 1200 Watt, hot-swappable, 1+1
redundant power supply units (PSU) |
Environment |
Power Consumption |
Online power calculator |
Input Voltage |
200 - 240 VAC, 50-60Hz |
Input Current |
5.7 A @ 200 VAC
|
Input Power |
1300W @ 200 VAC (all inputs) |
Heat Output |
4456 BTU/hr, 4702 Kj/hr |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)
Note: Above 900m (3000 ft), decrease in maximum temperature as altitude
increase, 1° C/300m (1.8° F/1000ft)
|
Humidity |
Operating: 10% to 80% relative humidity noncondensing, 27°
C (81° F) maximum wet bulb
Nonoperating: 85% relative humidity noncondensing, 38° C (100°
F) maximum wet bulb |
Altitude |
Operating: 0m to 3000m (9,840 ft.)
Nonoperating: 0m to 12000m (39,370 ft.) |
Vibration |
Operating: 0.15 G (vertical), 0.10 G (horizontal), 5 to 500 Hz,
swept-sine
|
Acoustic Noise |
Operating at 60%: 8.2 B (LwAd, 1B = 10dB)
Operating at 100%: 9.7 B (LwAd, 1B = 10dB)
Operating at 60%: 66.2 dBA - LpAm (energy average of four bystander positions)
Operating at 100%: 80.3 dBA - LpAm (energy average of four bystander positions) |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA-60950-1, EN60950-1, IEC 60950-1 CB Scheme with all country deviations |
Emissions |
FCC 47 CFR 15, ICES-003, EN55032, EN61000-3-2, and EN61000-3-3 |
Immunity |
EN55024 |
Certifications |
North American Safety (NRTL), European Union (EU), International CB Scheme, BIS (India),
BSMI (Taiwan), RCM (Australia), CCC (PRC), MSIP (Korea), VCCI (Japan) |
European Union Directives |
Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU,
Low Voltage Directive, 2014/35/EU, EMC Directive, 2014/30/EU, and (WEEE) 2012/19/EU
|
Dimensions and Weight |
Rack Units |
2U |
Height |
87.6 mm (3.5 in.) |
Width |
445.0 mm (17.5 in.) |
Depth |
737 mm (29 in.) |
Weight |
Appx 26.08 kg (57.5 lbs), without rackmount kit |
Clearance
and Service Access |
Front |
1232 mm (48.5 in.) |
Rear |
914.4 mm (36 in.) |
Airflow (front) |
50.8 mm (2 in.) |
Airflow (rear) |
76.2 mm (3 in.) |