Processor |
Number |
Two or Four SPARC M7 32-Core 4.133GHz processors |
Architecture |
SPARC V9 architecture, ECC protected |
CPUs |
- 4.133GHz 32-Core
- Up to 256 threads per processor (up to 8 threads per core)
- Cache Per Processor:
Level 1: 16 KB instruction and 16 KB data per core
Level 2: 256 KB L2 I$ per four cores, 256 KB L2 D$ per core pair
Level 3: 64 MB L3$ on chip
- Eight accelerators per processor, each supporting four concurrent in-memory query
operations with decompression
- Thirty-two on-chip encryption instruction accelerators with direct nonprivileged
for 15 industry-standard cryptographic algorithms: AES, Camellia, CRC32c, DES, 3DES, DH, DSA, ECC, MD5,
RSA, SHA-1, SHA-224, SHA-256, SHA384, SHA-512
|
Main Memory |
Capacities |
- Total DIMM slots:
64
- DIMM types:
- DIMM size:
16GB, 32GB or 64GB
- Maximum Configuation (2 processor): 2TB (32 × 64GB)
- Maximum Configuration (4 processor):
4TB (64 × 64GB)
|
Standard Integrated Interfaces
|
Network |
4 × 10 GbE 100Mbps/1Gbps/10Gbps ports, full duplex only, auto-negotiating (rear) |
Network Management |
One dedicated 10/100Base-T NET MGT port (rear)
Note: This port does not support connections to Gigabit networks. |
Serial Management |
Two RJ-45 SER MGT ports (1 front, 1 rear) |
Remote Management |
Onboard system processor, running Oracle Integrated Lights
Out Manager (ILOM) |
Graphics |
Two high-density DB-15 video ports (1 front, 1 rear) |
USB |
Front: 2 USB 3.0 Ports
Rear: 2 USB 3.0 Ports
Internal: 1 USB 2.0 Port |
PCI Expansion Slots |
16 low-profile PCI-Express 3.0 slots (eight x8 & eight x16) accessed via a PCIe hot-plug carrier
|
Internal Mass Storage |
Disks |
- 600GB or 1.2TB 2.5-inch SAS-3 disk drives (up to 8)
- 400GB, 800GB 2.5-inch SAS-3 solid state drives (up to 8)
- 1.6TB or 3.2TB NVMe solid state drives (up to 8 with optional NVMe switch cards)
- RAID 0, RAID 1, and RAID 1E support
|
Power Supplies |
4 × 3,000 Watt, hot-swappable, 2+2
redundant power supply units (PSU) |
Environment |
Power Consumption |
Online power calculator |
Voltage |
200 to 240 VAC |
Frequency |
50 to 60 Hz |
Maximum operating input current at 200 VAC |
22.9A (16A per cord) (Actual amperage draw may exceed rating by no more than
10%) |
Maximum operating input power at 200 VAC |
4,498W (Actual power draw may exceed rating by no more than 10%) |
Temperature |
Operating:
5° C to 35° C (41° F to 95° F)
Nonoperating:
-40° C to 65° C (-40° F to 149° F)
Note: Decrease in maximum temperature: above 900 m (2,952 ft.) 1° C/300 m (1.8° F/984 ft.)
|
Humidity |
Operating:
10% to 90% relative humidity noncondensing, 27° C (81° F) wet bulb
Nonoperating: 93% relative humidity, noncondensing, 38° C (100°
F) wet bulb |
Altitude |
Operating:
0m to 3000m (9,840 ft.) except in China markets where regulations may limit installations to a maximum altitude of 2,000 m
Nonoperating: 0m to 12000m (39,370 ft.) |
Acoustic Noise |
Operating at peak power:
9.4 B (LwAd, 1B = 10dB)
Operating/Idling: 79.7dB (LpAm, bystander positions) |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA 60950-1 (2nd Ed), EN 60950-1(2nd Ed), IEC 60950-1(2nd Ed) CB Scheme with all country deviations, CNS 14336-1 |
EMI/EMC |
FCC 47 CFR 15, ICES-003, EN55022, EN61000-3-2, EN61000-3-3 |
Immunity |
EN 55024
|
Regulatory Markings |
North America Safety (NRTL), European Union (EU), International CB Scheme, BIS (India),
BSMI (Taiwan), RCM (Australia), MSIP (Korea), VCCI (Japan)
|
European Union Directives |
Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Low Voltage Directive 2014/35/EU,
EMC Directive 2014/30/EU, and 2002/96/EC Waste Electrical and Electronic Equipment (WEEE) Directive, 2012/19/EU
|
Dimensions and Weight |
Height |
215 mm (8.5 in.) 5RU |
Width |
445 mm (17.5 in.) |
Depth |
835 mm (32.9 in.) |
Weight (approximations) |
Fully Populated: Appx 89.6 kg (197 lbs) (Includes two processor modules, 64 DIMMs, 8 disk drives, 16 PCIe cards, does not include rackmount kit or system packaging)
Half Populated: Appx 83.5 kg (184.1 lbs) (Includes one processor module, one processor filler module, 32 DIMMs, 8 disk drives, 16 PCIe cards, does not include rackmount kit or system packaging).
|
Clearance
and Service Access |
Front |
914.4 mm (36 in.) |
Rear |
914.4 mm (36 in.) |