Processor |
Number |
Two SPARC M7 32-Core 4.133GHz processors |
CPUs |
- Up to 256 threads per processor (up to 8 threads per core)
- Eight accelerators per processor, each supporting four concurrent in-memory query operations with decompression
- Thirty-two on-chip encrytion instruction accelerators with direct nonpriviledged support for 15
industry-standard cryptographic algorithms: AES, Camellia, CRC32c, DES, 3DES, DH, DSA, ECC,
MD5, RSA, SHA-1, SHA-224, SHA-256, SHA-384, SHA-512 (one per core)
- Thirty-two floating-point units per processor (one per core)
- One random number generator (one per processor)
|
Cache memory |
Level 1: 16KB instruction and 16 KB data per core, Level 2: 256 KB L2 I$ per four cores,
256 KB L2 D$ per core pair, Level 3: 64 MB L3$ on chip |
Main Memory |
Capacities |
- Total DIMM slots:
32 - 4 slots per memory riser, 4 memory risers per CPU, 8 total memory risers
- DIMM type: DDR4-2133
- DIMM size: 16GB, 32GB or 64GB
- Maximum capacity: 2TB (32 ×
64GB)
|
Standard Integrated Interfaces
|
Network |
4 × 10 GbE Ethernet ports (100 Mbps/1 Gbps/10 Gbps), full duplex only, auto-negotiating |
Network Management |
One dedicated 10/100Base-T RJ-45
port Ethernet port |
Serial Management |
One dedicated RJ-45 port |
Remote Management |
Onboard service processor, running Integrated Lights Out Manager
(ILOM) |
Graphics |
Two DB-15 VGA ports (one front, one rear) |
USB |
Front: 2 USB 2.0 Ports
Rear: 2 USB 3.0 Ports
Internal: 1 USB 3.0 Port |
PCI Expansion Slots |
- 8 low-profile PCI-Express 3.0 slots.
Slot # |
Physical |
Electrical |
1 |
x16 |
x16 |
2 |
x16 |
x16 |
3 |
x8 |
x8 |
4 |
x8 |
x8 |
5 |
x8 |
x8 |
6 |
x8 |
x8 |
7 |
x16 |
x16 |
8 |
x16 |
x16 |
|
Internal Mass Storage |
Disks |
- 600GB or 1.2TB 2.5-inch SAS-3 disk drives (up to 6)
- 400GB, 800GB 2.5-inch SAS-3 solid state drives (up to 6)
- 1.6TB or 3.2TB NVMe solid state drives (up to 4 with optional NVMe switch card)
- RAID 0, RAID 1, and RAID 1E support
|
DVD-ROM |
One Slimline SATA DVD +/-RW |
Power Supplies |
2 × 2000 Watt, hot-swappable, 1+1
redundant power supply units (PSU) |
Environment |
Input Voltage |
200 - 240 VAC, 50-60Hz |
Input Current |
10.75A @ 200 VAC (max) |
Input Power |
2475W @ 200 VAC (max) |
Maximum Heat Dissipation |
9,317 BTU/hr, 9830 KJ/hr |
Power Consumption |
Online
power calculator |
Temperature |
Operating: 5°
C to 35° C (41° F to 95° F)
Nonoperating:
-40° C to 65° C (-40° F to 149° F)
|
Humidity |
Operating:
10% to 90% relative humidity noncondensing, 27° C (81°
F) maximum wet bulb
Nonoperating:
Up to 93% relative humidity noncondensing, 38° C (100°
F) maximum wet bulb |
Altitude |
Operating:
0m to 3,000m (0 ft. to 9,840 ft), maximum ambient temperature is derated by 1°
C for every 300m above 900m (1.8° F for every 1000ft)
Nonoperating: 0m to 12,000m ( 0 ft. to 39,370 ft.)
|
Acoustic Noise |
Operating/Idling: 67.8 dBA / 80.4 dBA (LwAd, 1B = 10dB)
Operating/Idling: 7.7 B / 8.9 B (LpAm, bystander positions) |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA 60950-1, EN 60950-1 CB Scheme with all country deviations |
EMI/EMC |
FCC 47 CFR 15, ICES-003, EN 55022, EN61000-3-2,
EN61000-3-3 |
Immunity |
EN 55024 |
Certifications |
North American Safety (NRTL), European Union (EU), International CB Scheme,
BIS (India), BSMI (Taiwan), RCM (Australia), MSIP (Korea), VCCI (Japan) |
European Union Directives |
Restriction of Hazardous Substances
(RoHS) Directive 2011/65/EU, Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU, and Electronic Equipment (WEEE) Directive, 2012/19/EU
|
Dimensions and Weight |
Height |
129.8 mm (5.11 in.), 3U |
Width |
436.5 mm (17.185 in.) |
Depth |
752.5 mm (29.63 in.) |
Weight |
Max: 37.2 kg (82 lbs) max, without rackmount kit |
Clearance
and Service Access |
Front |
914.4 mm (36 in.) |
Rear |
914.4 mm (36 in.) |