Processor |
Number |
Up to eight SPARC T5 16-Core 3.6GHz processors |
Architecture |
SPARC V9 architecture, ECC protected |
CPUs |
- 3.6GHz 16-Core
- Up to 8 processors
- Up to 128 threads per processor for a maximum 1,024 threads per system
- Cache Per Processor: Shared 8 MB, 8 banked, Level 3 Cache; 128 KB Level 2 unified cache per core
- Sixteen floating-point units per SPARC T5 processor
- On-chip Encryption Instruction Accelerators with direct non-privileged support for 16 industry-standard cryptographic algorithms plus random number generation in each of the sixteen cores: AES, Camellia, CRC32c, DES, 3DES, DH, DSA, ECC, Kasumi, MD5, RSA, SHA-1, SHA-224, SHA-256, SHA-384, SHA-512
|
Cache memory |
4MB integrated L3 with a private L2 128K cache |
Main Memory |
Capacities |
- Total DIMM slots:
128
- DIMM type:
- DDR3L-1600/PC3L-12800 (runs at 1066 MHz)
- DDR3L-1333/PC3L-10600
- DIMM size:
16GB and 32GB
- Minimum Configuation: 2TB (128 × 16GB)
- Maximum capacity:
4TB (128 × 32GB)
|
Standard Integrated Interfaces
|
Network |
4 × 100Mbps/1Gbps/10Gbps ports (rear) |
Network Management |
One dedicated 10/100Base-T NET MGT port (rear)
Note: This port does not support connections to Gigabit networks. |
Serial Management |
Two RJ-45 SER MGT ports (1 front, 1r rear)
An additional serial management port is located on the main module and is
accessible from the front panel. |
Remote Management |
Onboard system processor, running Integrated Lights
Out Manager (ILOM) 3.21 |
Graphics |
Two high-density DB-15 video ports (1 front, 1 rear) |
USB |
Front: 2 USB 3.0 Ports
Rear: 2 USB 3.0 Ports
Internal: 2 USB 2.0 Ports |
PCI Expansion Slots |
16 low-profile PCI-Express 3.0 slots (x8 wired) accessed via a PCIe hot-plug carrier
|
Internal Mass Storage |
Disks |
- Up to eight 2.5-inch
SAS drives
- 300GB and 600GB 2.5-inch SAS disk drives, or 100 GB or 300 GB SSDs
- RAID 0, 1 and 1E support
|
Power Supplies |
4 × 3,000 Watt, hot-swappable, 2+2
redundant power supply units (PSU) |
Environment |
Power Consumption |
Online power calculator |
Voltage |
200 to 240 VAC |
Frequency |
50 to 60 Hz |
Maximum operating input current at 200-240 VAC |
30A (16A per cord) (Actual amperage draw may exceed rating by no more than
10%) |
Maximum operating input power at 200-240 VAC |
6000W (Actual power draw may exceed rating by no more than 10%) |
Maximum standby power |
260W |
Maximum heat dissipation |
22,185 BTU/hr, 23,504 KJ/hr |
Temperature |
Operating:
5° C to 35° C (41° F to 95° F)
Nonoperating:
-40° C to 65° C (-40° F to 149° F)
Note: Decrease in maximum temperature: above 900 m (2,952 ft.) 1° C/300 m (1.8° F/984 ft.)
|
Humidity |
Operating:
10% to 90% relative humidity noncondensing, 27° C (81° F) wet bulb
Nonoperating: 93% relative humidity, noncondensing, 38° C (100°
F) wet bulb |
Altitude |
Operating:
0m to 3000m (9,840 ft.) except in China markets where regulations may limit installations to a maximum altitude of 2,000 m
Nonoperating: 0m to 12000m (39,370 ft.) |
Vibration??? |
Vertical: 0.15G , 5-500Hz swept sine
Horizontal: 0.10G |
Shock??? |
3Gs, 11ms half-sine |
Acoustic Noise |
Operating at peak power:
83.2 dBA (LpAm: bystander positions)
10.0 B (LwAd, 1B = 10dB)
Operating/Idling: 65.7 dBA (LpAm: bystander positions)
8.2 B (LwAd 1 B = 10 dB) |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA 60950-1 (2nd Ed), EN 60950-1(2nd Ed), IEC 60950-1(2nd Ed) CB Scheme with all country deviations, CNS 14336-1 |
EMI/EMC |
EN 55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, CISPR22 Class A, CNS 13438 Class A, KN22 Class A, EN 61000-3-2, EN 61000-3-3 |
Immunity |
EN 55024 and KN24
|
Regulatory Markings |
CE, FCC, ICES-003, C-Tick, VCCI, GOST-R, BSMI, KC, cULus, S-Mark
|
European Union Directives |
Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU
|
Dimensions and Weight |
Height |
350 mm (13.8 in.) |
Width |
445 mm (17.5 in.) |
Depth |
800 mm (31.5 in.) |
Weight |
Appx 118.6 kg (261.5 lbs) (without rackmount kit) |
Clearance
and Service Access |
Front |
914.4 mm (36 in.) |
Rear |
914.4 mm (36 in.) |
Minimum airflow clearance (front) |
50.8 mm (2 in.) |
Minimum airflow clearance (rear) |
76.2 mm (3 in.)
|