Processor |
Number |
One or Two SPARC T5 16-Core 3.6GHz processors |
CPUs |
- Up to 128 threads per processor for a maximum of 256 threads per system
- Sixteen floating-point units per SPARC T5 processor
- Dual PCIe Gen3 interfaces
|
Cache memory |
16-KB instruction cache, 16-KB data cache, 1280-KB L2 cache,
8-MB L3 cache (8 banks, 16-way, set associative)
|
Main Memory |
Capacities |
- Total DIMM slots Dual Socket CPU Configuration:
32 - 4 slots per memory riser, 4 memory risers per CPU, 8 total memory risers
- Total DIMM slots Single Socket CPU Configuration:
16 - 4 slots per memory riser, 4 memory risers per CPU, 4 total memory risers
- DIMM type: DDR3
- DIMM size: 8GB, 16GB or 32GB
- Minimum Configruation Dual Socket CPU:
256GB. (32× 8GB or 16× 16GB)
- Minimum Configuration Single Socket CPU:
128GB (16× 8GB or 8× 16GB)
- Maximum capacity Dual Socket CPU: 1TB (32×
32GB)
- Maximum capacity Single Socket CPU: 512GB (32× 16GB or 16× 32GB)
|
Standard Integrated Interfaces
|
Network |
4 × 10 GbE Ethernet ports (100 Mbps/1 Gbps/10 Gbps) |
Network Management |
One dedicated 10/100Base-T RJ-45
port Ethernet port |
Serial Management |
One dedicated RJ-45 port |
Remote Management |
Onboard service processor, running Integrated Lights Out Manager
(ILOM) |
Graphics |
One DB-15 VGA port |
USB |
Front: 2 USB 2.0 Ports
Rear: 2 USB 3.0 Ports
Internal: 1 USB 3.0 Port |
PCI Expansion Slots |
- 8 low-profile PCI-Express 3.0 slots.
Slot # |
Physical |
Electrical |
1 |
x8 |
x8 |
2 |
x8 |
x8 |
3 |
x8 |
x8 |
4 |
x16 |
x8 |
5 |
x16 |
x8 |
6 |
x8 |
x8 |
7 |
x8 |
x8 |
8 |
x8 |
x8 |
|
Internal Mass Storage |
Disks |
- Up to six 2.5-inch SAS drives or SSD drives
- 300GB or 600GB 2.5-inch SAS disk drives
- 100GB or 300GB SSD drives
- RAID 0, RAID 1, and RAID 1E support
|
DVD-ROM |
1 slimline SATA DVD +/-RW |
Power Supplies |
2 × 2060 Watt, hot-swappable, 1+1
redundant power supply units (PSU) |
Environment |
Power Consumption |
Online power calculator |
Input Voltage |
200 - 240 VAC, 50-60Hz |
Input Current |
10.1A @ 200 VAC (max) |
Input Power |
1927.7W @ 200 VAC (max) |
Maximum Heat Dissipation |
4,953 BTU/hr, 5225.69 KJ/hr |
Power Consumption |
Online
power calculator |
Temperature |
Operating: 5°
C to 35° C (41° F to 95° F)
Nonoperating:
-40° C to 65° C (-40° F to 149° F)
|
Humidity |
Operating:
10% to 90% relative humidity noncondensing, 27° C (80.6°
F) maximum wet bulb
Nonoperating:
Up to 93% relative humidity noncondensing, 38° C (100.4°
F) maximum wet bulb |
Altitude |
Operating:
Up to 3000m (9840 ft), maximum ambient temperature is derated by 1°
C for every 300m above 900m (1.8° F for every 1000ft)
Nonoperating: Up to 12000m (39370 ft.)
|
Acoustic Noise |
Operating/Idling: 77 dB / 76 dB (LwAd, 1B = 10dB)
Operating/Idling: 61.5 B / 61.2 B (LpAm, bystander positions) |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA 60950-1 (2nd Ed), EN 60950-1
(2nd Ed), IEC 60950-1 (2nd Ed) CB Scheme with all country deviations, CNS
14336-1 |
EMI/EMC |
EN 55022 Class A, 47 CFR 15B Class A,
ICES-003 Class A, VCCI Class A, CISPR22 Class A, CNS 13438 Class A, KN22
Class A, EN 61000-3-2, EN
61000-3-3 |
Immunity |
EN 55024, KN24 |
Regulatory Markings |
CE, FCC, ICES-003, C-Tick, VCCI, GOST-R,
BSMI, KCC, cTUVus or cULus, S-Mark |
European Union Directives |
Restriction of Hazardous Substances
(RoHS) Directive 2011/65/EU |
Dimensions and Weight |
Height |
129.85 mm (5.11 in.), 3U |
Width |
436.5 mm (17.18 in.) |
Depth |
732 mm (28.81 in.) |
Weight |
Max: 36.28 kg (80 lbs) max, without rackmount kit |
Clearance
and Service Access |
Front |
914.4 mm (36 in.) |
Rear |
914.4 mm (36 in.) |