Processor
Number Single Socket.
Architecture Type:SPARC V9 architecture, ECC protected
  • Core/Speed/Threads: 16-Core, 3.6GHz, 128.
Cache Memory Shared 8 MB, 8 banked, L3; 128 KB Level 2 unified cache per core.
Main Memory
Capacities
  • Total DIMM slots: 16 on system board
  • DIMM type: DDR3
  • DIMM size: 8GB, 16GB or 32GB
  • Minimum Configuation: 128GB (16 × 8GB)
  • Maximum capacity: 512GB (16 × 32GB)
Internal Storage
Disk
  • Up to two internal 300 GB or 600 GB 10,000 rpm SAS disk drives, or 100 GB SATA solid state drives. The controller is capable of supporting integrated RAID levels 0, 1.
Management Environment
Service Processor (SP)
  • The SP card is installed with Oracle Integrated Lights-Out Manager (ILOM) software.
  • ILOM can be accessed via the RJ45 serial port provided by the Dongle cable assembly connected to the Universal Connector Port (UCP) on the front of the SPARC T5-1B.
  • The Dongle cable assembly is provided with the Sun Blade 6000 chassis and also orderable.
  • Built-in Integrated Lights Out Manager (ILOM) service provides the following features:
    • Accessible from the host operating system
    • Remote keyboard, video, mouse and storage (RKVMS)
    • Rich standards support:
    • WS-MAN
    • IPv6
    • SSH 2.0
    • LDAP, Microsoft Active Directory, and Radius Support
    • Email/SMTP alerts, fully configurable remote syslog
    • System serial console redirection via serial port and LAN
    • Integration with automatic service request (ASR) for qualified products to automatically initiate service when specific hardware faults occur
Standard Integrated Interfaces
Network
  • Two 10/100/1000 Base-T Ethernet ports using the Intel Ethernet Controller I350.
  • One dedicated 10/100 Base-T Ethernet port for the management network which can be optionally shared with the main network ports if desired.
Front Panel I/O Exposed via dongle cable:
  • One RJ-45 serial console to server module Oracle ILOM.
  • Three USB 2.0 ports (2 external via dongle and 1 internal accepting USB drive).
  • One VGA port.
Midplane I/O
  • Four x8 PCIe busses: Two dedicated to NEMs, two dedicated to EMs.
  • Four SAS-2 interfaces, two per NEM.
  • Two 10/100/1000 GbE interfaces, one per NEM.
  • 10/100 Ethernet management port to CMM.
  • Cards that are categorized as PCIe 3.0 are qualified to run with the T5-1B, however due to midplane restriction, will only run at 2.0 speeds. Between switch and CPU, the Blade runs at PCIe 3.0. However due to the midplane connector capabilities, from switch to the EM/NEM the speed is limited to PCIe 2.0.
Dimensions and Weights
Height 44.5mm (1.8 in).
Width 327.2mm (12.9 in).
Depth 511.7 (20.1 in).
Weight 7.7 kg (17 lbs). (fully configured)