Processor |
Number |
One or two SPARC S7 8-Core, 4.27GHz processors, not expandable |
CPUs |
- Up to 64 threads per processor (up to 8 threads per core)
- Four data analytics accelerators per processor, each supporting four
concurrent in-memory query operations with decompression
- Eight on-chip encrytion instruction accelerators with direct nonpriviledged
support for 15 industry-standard cryptographic algorithms: AES, Camellia,
CRC32c, DES, 3DES, DH, DSA, ECC, MD5, RSA, SHA-1, SHA-224, SHA-256,
SHA-384, SHA-512 (one per core)
- Eight floating-point units per processor (one per core)
- One random number generator (one per processor)
|
Cache memory |
Level 1: 16KB instruction and 16 KB data per core
Level 2: 256 KB L2 I$ per four cores, 256 KB L2 D$ per core pair
Level 3: 16 MB L3$ on chip |
Main Memory |
Capacities |
- DIMM slots: 8 slots per processor, supporting half or fully
populated configurations
- DIMM type: DDR4-2400
- DIMM size: 16GB, 32GB or 64GB
- Maximum capacity: 1024GB max configuration with 64GB DIMMs
and two processors
|
Standard Integrated Interfaces
|
Network |
4 × 10 GbE Ethernet ports (100 Mbps/1 Gbps/10 Gbps),
full duplex only, auto-negotiating |
Network Management |
One dedicated 10Mbps/100Mbps/1Gbps RJ-45 port Ethernet port |
Serial Management |
One dedicated RJ-45 port |
Remote Management |
Integrated Lights Out Manager (ILOM) |
USB |
Two USB 2.0 ports (front) |
PCI Expansion Slots |
- 3 low-profile PCI-Express 3.0 x8 slots.
Slot # |
Physical |
Electrical |
1 |
x16 |
x8 |
2 |
x16 |
x8 |
3 |
x8 |
x8 |
|
Internal Mass Storage |
Disks |
- 1 12Gbps SAS-3 controller
- Eight 2.5-inch SAS-3 disk drive slots (4 support NVMe)
- 600GB or 1.2TB 2.5-inch SAS-3 disk drives
- 400GB 2.5-inch SAS-3 solid state drives
- 800GB 2.5-inch SAS-3 solid state drives
- 1.6TB or 3.2TB NVMe solid state drives
- SAS-3 / NVMe mixing is supported.
|
Power Supplies |
2 × 800 or 1200 Watt, hot-swappable, N+1 redundant power
supply units (PSU) |
Environment |
Input Voltage |
100 to 120 VAC at 800W, 50/60Hz
200 to 240 VAC at 1200W, 50-60Hz |
Input Current |
4.1/8.6 A @ 100/200 VAC (max) |
Input Power |
851/819 W @ 100/200 VAC (max) |
Maximum Heat Dissipation |
2904 BTU/hr, 3064 KJ/hr |
Power Consumption |
Online
power calculator |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F) ; decrease
in maximum temperature: above 900 M (2952 ft) 1° C/300 m (1.8°/984
ft)
Nonoperating: -40° C to 65° C (-40° F to 149° F)
|
Humidity |
Operating: 10% to 90% relative humidity noncondensing,
27° C (81° F) maximum dew point
Nonoperating: 93% relative humidity noncondensing, 38° C (100°
F) maximum wet bulb |
Altitude |
Operating: 0m to 3,000m (0 ft. to 9,840 ft), except in China markets
where regulations may limit installations to a maximum altitude of 2000
m
Nonoperating: 0m to 12,000m ( 0 ft. to 39,370 ft.)
|
Acoustic Noise - Sound Power Level LwAD |
60% Fan Speed: 7.7 B (1 B = 10 dB)
100% Fan Speed: 8.6 B (1 B = 10 dB) |
Acoustic Noise - Sound Pressure LpAM |
60% Fan Speed: 62 dBA (avg of four bystander positions)
100% Fan Speed: 72 dBA (avg of four bystander positions) |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA 60950-1, EN 60950-1, IEC 60950-1 CB Scheme with all
country differences |
EMI/EMC |
FCC 47 CFR 15, ICES-003, EN 55022, EN61000-3-2, EN61000-3-3 |
Immunity |
EN 55024 |
Certifications |
North American Safety (NRTL), European Union (EU), International
CB Scheme, BIS (India), BSMI (Taiwan), RCM (Australia), CCC (PRC), MSIP
(Korea), VCCI (Japan), VNTA (Vietnam), Morocco, Republic of Srpska. |
European Union Directives |
Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU,
Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU, and WEEE Directive
2012/19/EU |
Dimensions and Weight |
Height |
43 mm (1.7 in.), 1U |
Width |
437 mm (17.2 in.) |
Depth |
737 mm (29 in.) |
Weight |
18 kg (40 lbs) max, without rackmount kit |
Clearance
and Service Access |
Front |
1232 mm (48.5 in.) |
Rear |
914.4 mm (36 in.) |