Processor |
Number |
Two to eight SPARC M8 32-Core 5.0GHz processors |
Architecture |
SPARC V9 architecture, ECC protected |
CPUs |
- 5.0GHz 32-Core
- Up to 8 processors
- Up to 256 threads per processor (8 threads per core)
- Cache:
Level 1: 32KB instruction and 16KB data per core
Level 2: 256KB L2 cache per 4-cores, 256KB L2 data cache per
core
Level 3: 64MB L3 cache on chip
- 32 floating-point units and 32 Oracle Numbers units per processor
(one per core)
- 32 on-chip encryption instruction accelerators (one per core) with
direct non-privileged support for 16 industry-standard cryptographic
algorithms: AES, Camellia, CRC32c, DES, 3DES, DH, DSA, ECC, MD5, RSA,
SHA-1, SHA-224, SHA-256, SHA-3, SHA-384, SHA-512
- 8 accelerators per processor, each supporting four concurrent in-memory
analytic engines with decompression
- 1 random number generator per processor
|
Main Memory |
Capacities |
- Total DIMM slots: 128 (16 per processor / CMIOU)
- DIMM type:
- DIMM size: 32GB or 64GB
- Minimum Configuration: 2TB (64 × 32GB)
- Maximum capacity: 8TB (128 × 64GB)
- Half and fully populated memory configurations supported
- Mixing memory DIMM sizes and rank types in a single CMIOU is not supported
- Memory size and type can differ between CMIOUs
|
Standard Integrated Interfaces
|
Network Management |
8 x 10/100/1000 Mb/sec RJ-45 ethernet ports (rear); 4 per service processor |
Serial Management |
8 x RJ-45 SER MGT ports (rear); 4 per service processor |
Remote Management |
2 service processors, running Integrated Lights Out Manager (ILOM). One
active, one standby. |
USB |
Each CMIOU hosts an eUSB device |
PCI Expansion Slots |
Up to 24 low-profile PCI-Express 3.0 slots (x16), each accessed via a
PCIe hot-plug carrier. 3 PCI-Express slots
per CMIOU. |
Domains |
1 or 2 physical domains can be ordered; this is set at the factory and
cannot be changed on-site. |
External Mass Storage |
No internal storage, connect to external storage. Oracle offers
a complete line of best-in-class, innovative storage, hardware, and software
solutions. For more information, please see oracle.com/storage
|
Power Supplies |
6× 3,000 Watt, hot-swappable, N+N redundant power supply
units (PSU)
SPARC M8-8s that are factory configured in a rack, there are two
Power Distribution Unit (PDU) options, with two PDUs each:
Low voltage (3x 200-220 VAC phase to phase, 60Hz, max line current 24A,
3 input cables)
High voltage (3x 200-240 VAC phase to neutral, 50Hz, max line current 16A,
3 input cables) |
Environment |
Power Consumption |
Online
power calculator |
Voltage |
200 to 240 VAC |
Frequency |
50/60 Hz |
Input Current |
16A @ 208 VAC |
Power Rating |
26 kVA per PDU |
Output Rating |
+12.3V @ 244A output |
Rated Power Supply Output Capacity |
3.0 KW |
Inrush Current |
50A peak (excluding EMI filter charging)
Less than 20A RMS over one cycle |
Power Consumption |
Max: 10400 W ; Typical: 6800 W |
Heat dissipation |
Max: 35500 BTU/hr / 37455 Kj/hr |
Temperature |
Operating:
0 - 500 m: 5° C to 35° C (41° F to 95° F)
501 to 1000 m: 5° C to 33° C (41° F to 93.2° F)
1001 to 1500 m: 5° C to 315° C (41° F to 87.7° F)
up to 3000 m: 5° C to 29° C (41° F to 84° F)
Except in China markets where regulations might limit installations to
a maximum of 2 km
Nonoperating:
maximum altitude 12000 m: 0° C to 50° C (32° F to 122°
F)
Note: Temperature ramp rate must not exceed 20° C (36° F) per
hour
|
Humidity |
Operating: 20% to 80% relative humidity noncondensing, 27°
C (81° F) max. wet bulb; Humidity ramp rate must not exceed 30% per
hour.
Nonoperating: up to 85% relative humidity, noncondensing, 40°
C (100° F) wet bulb; Max dew point 28° C. Humidity ramp rate must
not exceed 20% per hour. |
Altitude |
Operating: 0m to 3000m (9,840 ft.) except in China markets where
regulations may limit installations to a maximum altitude of 2,000 m
Nonoperating: 0m to 12000m (39,370 ft.) |
Acoustic Noise |
Operating at peak power: 85.7 dBA (bystander positions); 93.1 dBA
(sound power)
Operating/Idling: 76.7 dBA (bystander positions); 85.3 dBA (sound
power)
|
Aitflow Requirements |
Maximum: 860 CFM; typical: 590 CFM |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA 60950-1, EN 60950-1, IEC 60950-1 CB Scheme with all country deviations |
EMI/EMC |
FCC 47 CFR 15, ICES-003, EN 55022, EN 61000-3-11, EN 61000-3-12 |
Immunity |
EN 55024 |
Certifications |
North America Safety (NRTL), European Union (EU), International CB Scheme,
HSE Exemption (India), BSMI (Taiwan), RCM (Australia), MSIP (Korea), VCCI
(Japan) |
European Union Directives |
Restriction of Hazardous Substances (RoHS) Directive 2014/35/EU Low Voltage
Directive, 2014/30/EU EMC Directive, 2011/65/EU RoHS Directive, 2012/19/EU
WEEE Directive |
Dimensions and Weight |
Height |
Rack: 2000 mm (78.74 in)
Standalone: 438 mm (17.2 in), 10RU |
Width |
Rack: 600 mm (23.62 in)
Standalone: Width of server chassis:
445 mm (17.5 in); Width of server bezel: 483
mm (19.0 in) |
Depth |
Rack: Front door handle to rear door handle:
1200 mm (47.24 in); Without doors: 1112 mm (43.78 in)
Standalone: Depth of server chassis:
767 mm (30.2 in); Depth to rear component ejector levers: 813 mm (32.0 in) |
Weight |
Rack: ~416 kg (~917 lbs)
Standalone: 4 CMIOUs: 160 kg (353 lbs); 8 CMIOUs: 193 kg (425 lbs)
|
Clearance
and Service Access |
Minimum service clearance (front &
rear) |