Processor
Number Two to eight SPARC M7 32-Core 4.13GHz processors
Architecture SPARC V9 architecture, ECC protected
CPUs
  • 4.13GHz 32-Core
  • Up to 8 processors
  • Up to 256 threads per processor (8 threads per core)
  • Cache:
    Level 1: 16 KB instruction and 16 KB data per core
    Level 2: 256 KB L2 cache per 4-cores, 256 KB L2 data cache per core pair
    Level 3: 64 MB L3 cache on chip
  • 32 floating-point units per SPARC M7 processor (one per core)
  • 32 on-chip encryption instruction accelerators with direct non-privileged support for 15 industry-standard cryptographic algorithms: AES, Camellia, CRC32c, DES, 3DES, DH, DSA, ECC, MD5, RSA, SHA-1, SHA-224, SHA-256, SHA-384, SHA-512
  • 8 accelerators per processor, each supporting four concurrent query operations with decompression
  • 1 random number generator per processor
Main Memory
Capacities
  • Total DIMM slots: 128 (16 per processor / CMIOU)
  • DIMM type:
    • DDR4-2133
  • DIMM size:16GB, 32GB or 64GB
  • Minimum Configuration: 1TB (64 × 16GB)
  • Maximum capacity: 8TB (128 × 64GB)
  • Half and fully populated memory configurations supported
  • Mixing memory DIMM sizes and rank types in a single CMIOU is not supported
  • Memory size and type can differ between CMIOUs
Standard Integrated Interfaces
Network Management 8 x 10/100/1000 Mb/sec RJ-45 ethernet ports (rear); 4 per service processor
Serial Management 8 x RJ-45 SER MGT ports (rear); 4 per service processor
Remote Management 2 system processors, running Integrated Lights Out Manager (ILOM). One active, one standby.
USB Each CMIOU hosts an eUSB device
PCI Expansion Slots Up to 24 low-profile PCI-Express 3.0 slots (x16), each accessed via a PCIe hot-plug carrier. 3 PCI-Express slots per CMIOU.
Domains 1 or 2 physical domains can be ordered; this is set at the factory and cannot be changed on-site.
External Mass Storage
No internal storage, connect to external storage. Oracle offers a complete line of best-in-class, innovative storage, hardware, and software solutions. For more information, please see oracle.com/storage
Power Supplies
6× 3,000 Watt, hot-swappable, 3+3 redundant power supply units (PSU)
SPARC M7-8s that are factory configured in a rack, there are two Power Distribution Unit (PDU) options, with two PDUs each:
Low voltage (3x 115/200 - 127/220 VAC 3-phase, 50/60 Hz max, 24A per phase)
High voltage (3x 220/380 - 240/415 VAC 3-phase, 50/60 Hz, max, 16A per phase)
Environment
Power Consumption Online power calculator
Voltage 200 to 240 VAC
Frequency 50 to 60 Hz
Input Current 16A @ 208 VAC
Power Rating 22 kVA per PDU
Output Rating +12.3V @ 244A output
Rated Power Supply Output Capacity 3.0 KW
Inrush Current 50A peak (excluding EMI filter charging)
Less than 20A RMS over one cycle
Power Consumption Max: 10400 W ; Typical: 6800 W
Heat dissipation Max: 35500 BTU/hr / 37455 Kj/hr
Temperature

Operating:
0 - 500 m: 5° C to 35° C (41° F to 95° F)
501 to 1000 m: 5° C to 33° C (41° F to 93.2° F)
1001 to 1500 m: 5° C to 315° C (41° F to 87.7° F)
up to 3000 m: 5° C to 29° C (41° F to 84° F)
Except in China markets where regulations might limit installations to a maximum of 2 km

Nonoperating:
maximum altitude 12000 m: 0° C to 50° C (32° F to 122° F)

Humidity Operating: 20% to 80% relative humidity noncondensing, 27° C (81° F) max. wet bulb; Humidity ramp rate must not exceed 30% per hour.
Nonoperating: up to 85% relative humidity, noncondensing, 40° C (100° F) wet bulb; Max dew point 28° C. Humidity ramp rate must not exceed 20% per hour.
Altitude Operating: 0m to 3000m (9,840 ft.) except in China markets where regulations may limit installations to a maximum altitude of 2,000 m
Nonoperating: 0m to 12000m (39,370 ft.)
Acoustic Noise Operating at peak power: 85.7 dBA (bystander positions); 93.1 dBA (sound power)
Operating/Idling: 76.7 dBA (bystander positions); 85.3 dBA (sound power)
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA 60950-1, EN 60950-1, IEC 60950-1(2nd Ed) CB Scheme with all country deviations
EMI/EMC FCC 47 CFR 15, ICES-003, EN 55022, EN 61000-3-11, EN 61000-3-12
Immunity EN 55024
Certifications North America Safety (NRTL), European Union (EU), International CB Scheme, HSE Exemption (India), BSMI (Taiwan), RCM (Australia), MSIP (Korea), VCCI (Japan)
European Union Directives Restriction of Hazardous Substances (RoHS) Directive 2014/35/EU Low Voltage Directive, 2014/30/EU EMC Directive, 2011/65/EU RoHS Directive, 2012/19/EU WEEE Directive
Dimensions and Weight
Height Rack: 1998 mm (78.66 in)
Standalone: 438 mm (17.2 in), 10RU
Width Rack: 600 mm (23.62 in)
Standalone: Width of server chassis: 445 mm (17.5 in); Width of server bezel: 483 mm (19.0 in)
Depth Rack: Front door handle to rear door handle: 1200 mm (47.24 in); Without doors: 1112 mm (43.78 in)
Standalone: Depth of server chassis: 767 mm (30.2 in); Depth to rear component ejector levers: 813 mm (32.0 in)
Weight

Rack: ~ 374 kg (~824 lbs)
Standalone: 4 CMIOUs: 136 kg (300 lbs); 8 CMIOUs: 184 kg (405 lbs)

Clearance and Service Access
Minimum service clearance (front & rear) 914 mm (36 in)