SPARC M7-16 Server: Hardware Specifications
Processor |
Number |
Four to sixteen SPARC M7 32-Core 4.133GHz processors |
Architecture |
SPARC V9 architecture, ECC protected |
CPUs |
- 4.133GHz 32-Core
- Up to 16 processors
- Up to 256 threads per processor (8 threads per core)
- Cache:
Level 1: 16 KB instruction and 16 KB data per core
Level 2: 256 KB L2 cache per 4-cores, 256 KB L2 data cache per core
pair
Level 3: 64 MB L3 cache on chip
- 32 floating-point units per SPARC M7 processor (one per core)
- 32 on-chip encryption instruction accelerators with direct non-privileged
support for 15 industry-standard cryptographic algorithms: AES, Camellia,
CRC32c, DES, 3DES, DH, DSA, ECC, MD5, RSA, SHA-1, SHA-224, SHA-256,
SHA-384, SHA-512
- 8 accelerators per processor, each supporting four concurrent query
operations with decompression
- 1 random number generator per processor
|
Main Memory |
Capacities |
- Total DIMM slots: 256 (16 per processor / CMIOU)
- DIMM type: DDR4-2133
- DIMM size: 16GB, 32GB or 64GB
- Minimum Configuration: 1TB (4 CMIOUs × 16 slots × 16GB)
- Maximum capacity: 16TB (16 CMIOUs × 16 slots × 64GB)
- Mixing memory DIMM sizes and rank types in a single CMIOU is not supported
- Half and fully populated memory configurations supported
|
Standard Integrated Interfaces
|
PCI Expansion Slots |
Up to 48 low-profile PCI-Express 3.0 slots (x16), each accessed via a
PCIe hot-plug carrier |
External Mass Storage |
No internal storage, connect to external storage. Oracle offers
a complete line of best-in-class, innovative storage, hardware, and software
solutions. For more information, please see oracle.com/storage
|
Power Supplies |
6×
16× 3,000 Watt, hot-swappable, power supplies with N+N redundancy.
Nominal AC operating voltage range 200 to 240 VAC.
Two three phase PDU options with two PDUs each:
- Low Voltage (3× 115/200 - 127/220 VAC 3 phase, 50/60 Hz, max. 24A per phase).
- High Voltage (3× 220/380 -240/415 VAC 3 phase, 50/60 Hz, max. 16A per phase).
|
Environment |
Power Consumption |
Online
power calculator |
Temperature |
Operating:
5° to 35° C (41° to 95° F) at 0 to 500 m (0 to 1,640 ft.)
5° to 33° C (41° to 93.2° F) at 501 to 1,000 m (1,664 to 3,281 ft.)
5° to 31° C (41° to 87.7° F) at 1,001 to 1,500 m (3,284 ft. to 4,921 ft,)
5° C to 29° C (41° F to 84° F) up to 3,000 m (10,000 ft.)
Nonoperating:
0° C to 50° C (32° F to 122° F), maximum altitude 12,000 m (40,000 ft.)
|
Humidity |
Operating Relative Humidity: 20% to 80%, 27° C (81° F) max. wet
bulb temperature, noncondensing
Note: Humidity ramp rate must not exceed 30% per hour
Nonoperating Relative Humidity: 93%, noncondensing, 38° C (100.4° F) wet bulb
|
Altitude |
Operating: 0m to 3000m (10,000 ft.) except in China markets where
regulations may limit installations to a maximum altitude of 2,000 m (6560 ft.).
Nonoperating: 0m to 12000m (40,000 ft.) |
Acoustic Noise |
Operating at peak power: 85.7 dBA (bystander positions); 93.1 dBA
(sound power)
Operating/Idling: 8.2 B (LwAd 1 B = 10 dB)
65.7 dBA (LpAm: bystander positions)
Operating at peak power: 10 B (LwAd 1 B = 10 dB)
83.2 dBA (LpAm: bystander positions)
|
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA 60950-1, EN 60950-1, IEC 60950-1(2nd Ed) CB Scheme with all country
deviations |
EMC |
Emissions: FCC 47 CFR 15, ICES-003, EN55022, EN61000-3-2, EN61000-3-3 |
Immunity |
EN 55024 |
Certifications |
North America Safety (NRTL), European Union (EU), International CB Scheme,
BIS (India), BSMI (Taiwan), RCM (Australia), MSIP (Korea), VCCI
(Japan) |
European Union Directives |
Restriction of Hazardous Substances (RoHS) Directive 2014/35/EU Low Voltage
Directive, 2014/30/EU EMC Directive, 2011/65/EU RoHS Directive, 2012/19/EU
WEEE Directive |
Dimensions and Weight |
1200 mm Oracle Rack Dimensions |
Rack: 23.62"W × 47.24"D × 78.66"H) |
Maximum Weight |
749 kg (1,650 lbs) (varies by configuration)
|
|