| Standard
Integrated Interfaces |
| Connection Method |
Link Board (PCILINKBD_B) connects to Link Card (PCILINK_B) on the server side.
|
| PCI Expansion Slots |
Eleven PCI Express 3.0 slots
One PCI slot dedicated to the Link Board (PCILINKBD_B) |
| Power Supplies |
Dual redundant, Dual power feed, hot swappable power supplies
|
| Environment |
| AC power |
100-120 / 200-240 VAC (1-phase) |
| Temperature |
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -25° C to 60° C (-13° F to 140° F)(unpacked)
|
| Humidity |
Single, non-rack system:
Operating: 20% to 80% relative humidity noncondensing
Nonoperating: 20% to 80% relative humidity noncondensing (unpacked) |
| Altitude |
Single, non-rack system:
Operating: up to 3000 m (9,843 ft.), maximum ambient
temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.) |
| Dimensions and Weight |
| Height |
86 mm (3.39 in.) |
| Width |
440 mm (17.32 in.) |
| Depth |
740 mm (29.13 in.) |
| Weight |
22 kg (48.5 lb.) minimum (no PCI-Express cards installed), 23.44 kg (51.67 lb.) maximum assuming
PCI-Express card weighs 0.12 kg (0.25 lb.) each, and without the rack mounting slide rail kit installed.
|
| Rack Mounting |
| Fujitsu M10 PCI Expansion Unit Racks |
Racks are as follows:
- Fujitsu Expansion Rack
- Sun Rack II 1242
- Sun Rack II 1042
- Sun Rack 900-38
- Sun Rack1000-38
- Sun Rack1000-42
- Sun Rack 900-36N
|