| Processor |
| Number |
Two or Four 16-Core (4 socket, 128 Threads) |
| Architecture |
Type: SPARC64 16-Core Processor |
| CPUs original M10-4S |
SPARC 3.0GHz 16-Core (24MB L2 - 24way)
Two CPU's on the Upper CPU/Memory Unit (CMUUQN)
Two CPU's on the Lower CPU/Memory Unit (CMULQN)
|
| CPUs M10-4S+ |
SPARC 3.7GHz 16-Core (24MB L2 - 24way)
Two CPU's on the Upper CPU/Memory Unit (CMUUQNB)
Two CPU's on the Lower CPU/Memory Unit (CMULQNB)
|
| Note: |
There is no upgrade path from the original M10-4S to the M10-4S+
|
| Main Memory |
| Capacities |
Total DIMM slots: 16 per CPU socket (64 total DIMM slots x 4 CPU sockets)
DIMM type: DDR3 1066MHz or 1333MHz Registered DIMMs
DIMM size: 32GB 1333MHz or 8GB, 16GB 1066MHz
Maximum capacity: 2TB (when configured with 32GB DIMMs)
|
| Standard
Integrated Interfaces |
| Network |
Four 1GbE Ethernet Ports
|
| Service Processor |
One dedicated TIA/EIA-232-F asynchronous RJ45 port
One USB Maintenance port
Two 1GbE Ethernet Ports
|
| SAS |
One 6Gbps channel SAS interface (4 wide) |
| USB |
Front: One USB 2.0 port
Rear: One USB 2.0 port |
| PCI Expansion Slots |
Eight low profile PCI Express 3.0 slots
(8 x8 electrical/mechanical) |
| Internal Mass Storage |
| Disks |
Up to eight front accessible disk bays with 2.5" SAS disks or eight solid-state drives (SSDs)
Drive Type
|
Density
|
Speed
|
Form Factor
|
SAS
|
600 GB
|
10,000 RPM
|
2.5"
|
SAS
|
900 GB
|
10,000 RPM
|
2.5"
|
SAS Solid State Drive
|
100 GB
|
NA
|
2.5"
|
SAS Solid State Drive
|
200 GB
|
NA
|
2.5"
|
|
| XB-Box
(Crossbar box) (XBUQ) |
| Number of Building Block Modules that can be connected |
XB-Box x 2 (4Ux2) = up to 32 CPU's or sockets
XB-Box x 4 (4Ux4) = up to 64 CPU's or sockets
Note: Used to connect BB Modules for system configurations larger than 16 CPU's or sockets (4BBs)
|
| Interconnect |
14.5 GB high-speed interconnect x 48 port
|
| Service Processor |
Redundant with XB-Box configuration.
XSCF in XB-Box becomes Master.
Two XB-Boxes provide redundancy (Master-Slave roles). |
| Power Supplies |
Dual redundant, hot swappable power supplies (PSUQ)
50Hz/60Hz in single phase
Maximum power consumption = 2,765 W
Heat dissipation = 9,360 kj/hr (8,872 BTU/hr)
|
| Environment |
| AC power |
200-240 VAC (1-phase) |
| Temperature |
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -25° C to 60° C (-13° F to 140° F)(unpacked)
|
| Humidity |
Single, non-rack system:
Operating: 20% to 80% relative humidity noncondensing
Nonoperating: 20% to 80% relative humidity noncondensing (unpacked) |
| Altitude |
Single, non-rack system:
Operating: up to 3000 m (9,843 ft.), maximum ambient
temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.) |
| Dimensions and Weight |
| Height |
175 mm (6.89 in.) |
| Width |
440 mm (17.32in.) |
| Depth |
810 mm (31.89 in.) |
| Weight |
60 kg (132.27 lb.) |
| Rack Mounting |
| Fujitsu M10-4 Server Rack |
Rack is as follows:
- Fujitsu Expansion Rack
- Sun Rack II 1042
- Sun Rack II 1242
- Sun Rack 900-38
- Sun Rack 1000-38
- Sun Rack 1000-42
- Sun Rack 900-36N
|