Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Fujitsu M10-1 Server: Hardware Specifications

Processor
Number One 16-Core (one socket) or One 8-Core (one socket)
Architecture Type: SPARC64 16-Core Processor or SPARC64 X+ 8-Core Processor
CPUs original M10-1 SPARC 2.8GHz 16-Core (22MB L2 - 22way)
CPUs M10-1+ SPARC 3.2GHz 16-Core (22MB L2 - 22way)
CPUs M10-1+ SPARC 3.7GHz 8-Core (24MB L2)
Note: There is no upgrade path from the original M10-1 to the M10-1+ or M10-1+ (3.7GHz 8-Core)
Main Memory
Capacities Total DIMM slots: 16
DIMM type: DDR3 1066MHz or 1333MHz Registered DIMMs
DIMM size: 32GB 1333MHz or 8GB, 16GB 1066MHz
Maximum capacity: 512GB (when configured with 32GB DIMMs)
Standard Integrated Interfaces
Network Four 1GbE Ethernet Ports
Service Processor One dedicated TIA/EIA-232-F asynchronous RJ45 port
One USB Maintenance port
Two 1GbE Ethernet Ports
SAS One 6Gbps channel SAS interface
USB Front: One USB 2.0 ports
Rear: One USB 2.0 ports
PCI Expansion Slots Three low profile PCI Express 3.0 slots (3 x8 electrical/mechanical)
Internal Mass Storage
Disks Up to eight front accessible disk bays with 2.5" SAS disks or eight solid-state drives (SSDs)
Drive Type
Density
Speed
Form Factor
SAS
900 GB
10,000 RPM
2.5"
SAS
600 GB
10,000 RPM
2.5"
SAS Solid State Drive
100 GB
NA
2.5"
SAS Solid State Drive
200 GB
NA
2.5"
Power Supplies
Dual redundant, hot swappable power supplies
Maximum AC input = Max 763W (at 100-120VAC), Max 740W (at 200-240VAC)
Environment
AC power 100-120 / 200-240 VAC (1-phase)
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -25° C to 60° C (-13° F to 140° F)(unpacked)
Humidity Single, non-rack system:
Operating: 20% to 80% relative humidity noncondensing
Nonoperating: 20% to 80% relative humidity noncondensing (unpacked)
Altitude Single, non-rack system:
Operating: up to 3000 m (9,843 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.)
Dimensions and Weight
Height 42.5 mm (1.67 in.)
Width 431 mm (16.97 in.)
Depth 721 mm (28.39 in.)
Weight 18 kg (39.68 lb.) maximum assuming PCI-Express card weighs 0.12 kg
(0.25 lb) each, and without the rack mounting slide rail kit installed.
Rack Mounting
Fujitsu M10-1 Server Rack Rack is as follows:
  • Fujitsu Expansion Rack
  • Sun Rack II 1042
  • Sun Rack II 1242
  • Sun Rack 900-38
  • Sun Rack 1000-38
  • Sun Rack 1000-42
  • Sun Rack 900-36N

  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
 Feedback