StorageTek SL150 Modular Tape Library: Hardware Specifications

Tape Drives
1 to 30 LTO5, LTO6, LTO7, or LTO8 FC or SAS half height drives
30 to 450 cartridge slots (Base Module 30 slots, up to 14 expansion modules with 30 slots each)
Base Module Mail Slot - 4-cartridge capacity
Environment
Power Consumption Online power calculator
Input Voltage 100-240 V
Frequency 50-60 Hz single phase (auto-ranging)
Output 157.5 Watts (max) (each Base/Expansion Module)
Operating Max 1.42 A @ 120 V or 0.75 A@ 240 V (Library - continuous, not peak)
Heat Output 614 BTU/hr
Temperature & Humidity Operating: 10° C to 40° C (50° F to 104° F), 20% to 80% noncondensing
Nonoperating: -40° C to 60° C (-40° F to 140° F), 10% to 95% noncondensing
Dimensions and Weights
Height Base Module: 13.08 cm (5.15 in), 3U
Expansion Module: 8.89 cm (3.5 in), 2U
Width 48.1 cm (18.94 in)
Depth 92.5 cm (36.4 in.), including 2.25 in. tape drive extension
Weight Base Module: 27.2 kg (60 lb) including both magazines, robot, 2 tape drives, and 2 power supplies
Expansion Module: 14.1 kg (31 pounds) including both magazines, 2 tape drives, and 2 power supplies
Regulations
Safety UL 60950-1, CAN/CSA 22.2 No. 60950-1-07, EN 60950-1, IEC 60950-1, 60825-1, Class 1 Laser Product
RFI/EMI FCC (47CFR15 Subpart B) Class A; EN55022 Class A; EN55024; EN61000-3-2; EN61000-3-3; ICES-003 Class A; AS/NZS CISPR22 Class A; VCCI V-3 Class A; KN22 Class A; KN24; CNS13438 Class A
Capacity and Performance
Performance

LTO5: 20 drives, 140 MB/sec each = 10 TB/hour
LTO6: 20 drives, 160 MB/sec each = 11.5 TB/hr

LTO7: 8 drives, 300 MB/sec each = 8.2 TB/hr
LTO8: 8 drives, 300 MB/sec each = 8.2 TB/hr

Capacity LTO5: 1.5 TB/cartridge, 300 cartridges = 450 TB
LTO6: 2.5 TB/cartridge, 300 cartridges = 750 TB

LTO7: 6 TB/cartridge, 120 cartridges = 720 TB
LTO8: 12 TB/cartridge, 120 cartridges = 1440 TB
Clearance
96.5 cm (38 in) rear service clearance
In a rack, leave 1U of space under the bottom expansion module for service clearance
The StorageTek SL150 rack requirements:
  • Sun Rack II, standard Oracle 19-inch rack

 


  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.