Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Oracle Server X7-8: Hardware Specifications


Processor
Number 4 or 8 CMODs (Compute Modules), providing 4 or 8 CPU configurations
Architecture Type (4-socket or 8-socket server):
  • Intel Xeon 8160 Processor Series
  • Intel Xeon 8168 Processor Series
  • Type (4-socket server):
  • Intel Xeon 6128 Processor Series
  • Intel Xeon 9140 Processor Series

  • 8-socket configurations support up to 24-core (shelf 4) processors for total of 192 cores.
  • 4-socket configurations support up to 24-core (shelf 4) processors for total of 96 cores.
  • CPUs Intel 3.4GHz 6-Core Xeon 6128, 115W, SR3J4
    Intel 2.3GHz 18-Core Xeon 6140, 140W, SR3AX
    Intel 2.1GHz 24-Core Xeon 8160, 150W, SR3B0
    Intel 2.7GHz 24-Core Xeon 8168, 205W, SR37J
    Main Memory
    Capacities
  • DIMM Slots per CMOD:12
  • Total DIMM Slots:48 (4-processor configuration) or 96 (8-processor configuration)
  • DIMM Size and Type: 16GB: DDR4-2666 Registered DIMM or 32GB: DDR4-2666 Registered DIMM (RDIMM) or 64GB: DDR4-2666 Load Reduced DIMM (LRDIMM)
  • Minimum Populated DIMM Slots per CMOD: Each PM can only be configured with either (6) or (12) DIMM slots populated
  • Minimum Memory Capacity: 384GB (4-processor configuration) or 768GB (8-processor configuration) using 16GB DIMMs
  • Maximum Memory Capacity:3TB (4-processor configuration) or 6TB (8-processor configuration) using 64GB DIMMs
  • Memory capacity needs to be equal across all CMODs
  • Memory mixing is not allowed
  • Standard I/O
    Network Four 10GBASE-T ports per server module (SMOD) (NET0-3)
    Network Management One external network management (NET MGT) port per SMOD
    Serial Management One external RJ-45 serial management (SER MGT) port per SMOD
    USB 1 external USB 3.0 port per SMOD
    PCI Expansion Slots
    • 16 low-profile PCI-Express 3.0 slots.
    • Internal PCIe slots are located within Dual PCIe Card Carriers (DPCCs), which support standard low-profile (LP) PCIe adapters. The DPCCs for the Oracle Server X7-8 are rear-accessible and hot-swappable.
    • The DPCCs essentially make standard PCIe adapters hot-swappable components.
    • There are (8) empty DPCCs included in each (SMOD).
    • In dual 4-socket mode, each side has four x8 and four x16 PCIe slots.
    • In 8-socket mode, SMOD0 A has eight x8 and eight x16 PCIe slots.
    • Each service module controls eight PCIe slots.
    Slot # Physical Electrical
    1 x16 x16
    2 x8 x8
    3 x16 x16
    4 x8 x8
    5 x16 x16
    6 x8 x8
    7 x16 x16
    8 x8 x8
    9 x16 x16
    10 x8 x8
    11 x16 x16
    12 x8 x8
    13 x16 x16
    14 x8 x8
    15 x16 x16
    16 x8 x8
    Internal Mass Storage
    Disks
    • Up to eight rear-accessible 2.5-inch SAS-3 drives; hot-swappable
    • 600GB or 800GB or 1.2TB 2.5-inch SAS-3 disk drives
    • 6.4TB NVMe Drives, maximum of eight
    Power Supplies and Fans
    • Four redundant, hot-swappable back panel accessible power supplies; 3000W
    • Eight 80mm hot-swappable, redundant fan modules at chassis front
    Environment
    Power Consumption Online power calculator
    Input Voltage 200 - 240 VAC, 50-60Hz
    Maximum Heat Output 13475 BTU/hr
    Temperature Operating: 5° C to 35° C (41° F to 95° F) up to 900 meters (2,953 ft)
    Nonoperating: -40° C to 68° C (-40° F to 154°F)
    Note: Maximum ambient operating temperature is derated by 1° C per every 300m (984 ft) elevation beyond 900m (3000 ft), up to a maximum altitude of 3,000m (9842 ft) elevation.
    Humidity Operating: 10% to 90% noncondensing, short term -5° C to 55° C (25° F to 113° F)
    5% to 90% noncondensing, but not to exceed 0.024kg of water per kg of dry air (0.053 lbs warer/2.205 lbs dry air)
    Nonoperating: Up to 93% noncondensing 35° C (95° F) maximum wet bulb
    Altitude Operating: Up to 3000m (9,840 ft) at 35° C (95° F)
    Note: In China markets, regulations might limit installations to a maximum altitude of 2000m (6562 ft).
    Nonoperating: 0 to 12,000m (39,370 ft)
    Acoustic Noise Emissions Maximum Condition: 8.1 Bels
    Idle Condition: 5.8 Bels
    Vibration Operating: 0.15 G (z-axis)
    0.10 G (x-, y-axes), 5-500Hz swept sine
    Nonoperating: 0.5 G (z-axis)
    0.25 G (x-, y-axes), 5-500Hz swept sine
    Shock Operating: 3 Gs, 11 ms half-sine
    Nonoperating:
    Roll Off: 1.25 inch roll-off free fall, front to back rolling directions.
    Threshold: 13mm threshold height at 0.65 m/s impact velocity.
    Regulations
    Meets or exceeds the following requirements:
    Safety UL/CSA 60950-1, EN 60950-1, IEC 60950-1 (CB Scheme with all country differences)
    EMC Emissions: FCC 47 CFR Part 15, ICES-003, EN 55032, EN610000-3-11, EN61000-3-12
    Emissions and Immunity EN55024
    Certifications
    Safety Marks North America (NRTL), European Union (EU), International CB Scheme, HSE Exemption (India), BSMI (Taiwan), RCM (Australia), MSIP (Korea), VCCI (Japan), Morocco, Republic of Srpska, Vietnam
    European Union Directives 2014/35/EU Low Voltage Directive, 2014/30/EU EMC Directive, 2011/65/EU RoHS Directive, 2012/19/EU WEEE Directive
    Dimensions and Weight
    Height 21.9 cm (8.62 in.) 5U
    Width 44.6 cm (23.62 in.)
    Depth 85 cm (33.6 in.)
    Weight Maximum: 114 kg (250 lbs.)
    Rack Mounting & Clearance
    Maintenance Space Requirements
    • Above the rack clearance: 91.4 cm (36 in)
    • Front Minimum Clearance: 123.2 cm (48.5 in)
    • Rear Minimum Clearance: 91.4 cm (36 in)

      Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.