Processor |
Number |
4 or 8 CMODs (Compute Modules), providing 4 or 8 CPU configurations |
Architecture |
Type (4-socket or 8-socket server):
- Intel Xeon 8160 Processor Series
- Intel Xeon 8168 Processor Series
Type (4-socket server):
- Intel Xeon 6128 Processor Series
- Intel Xeon 9140 Processor Series
- 8-socket configurations support up to 24-core (shelf 4) processors for total of 192 cores.
- 4-socket configurations support up to 24-core (shelf 4) processors for total of 96 cores.
|
CPUs |
Intel 3.4GHz 6-Core Xeon 6128, 115W, SR3J4
Intel 2.3GHz 18-Core Xeon 6140, 140W, SR3AX
Intel 2.1GHz 24-Core Xeon 8160, 150W, SR3B0
Intel 2.7GHz 24-Core Xeon 8168, 205W, SR37J
|
Main
Memory |
Capacities |
- DIMM Slots per CMOD:12
- Total DIMM Slots:48 (4-processor configuration) or 96 (8-processor configuration)
- DIMM Size and Type: 16GB: DDR4-2666 Registered DIMM or 32GB:
DDR4-2666 Registered DIMM (RDIMM) or 64GB: DDR4-2666 Load Reduced DIMM (LRDIMM)
- Minimum Populated DIMM Slots per CMOD: Each PM can only be configured with either (6) or (12) DIMM slots populated
- Minimum Memory Capacity: 384GB (4-processor configuration) or 768GB (8-processor configuration) using 16GB DIMMs
- Maximum Memory Capacity:3TB (4-processor configuration) or 6TB (8-processor configuration) using 64GB DIMMs
- Memory capacity needs to be equal across all CMODs
- Memory mixing is not allowed
|
Standard
I/O |
Network |
Four 10GBASE-T ports per server module (SMOD) (NET0-3) |
Network Management |
One external network management (NET MGT) port per SMOD |
Serial Management |
One external RJ-45 serial management (SER MGT) port per SMOD |
USB |
1 external USB 3.0 port per SMOD |
PCI Expansion Slots |
- 16 low-profile PCI-Express 3.0 slots.
- Internal PCIe slots are located within Dual PCIe Card Carriers (DPCCs), which support standard low-profile (LP) PCIe adapters. The DPCCs for the Oracle Server X7-8 are rear-accessible and hot-swappable.
- The DPCCs essentially make standard PCIe adapters hot-swappable components.
- There are (8) empty DPCCs included in each (SMOD).
- In dual 4-socket mode, each side has four x8 and four x16 PCIe slots.
- In 8-socket mode, SMOD0 A has eight x8 and eight x16 PCIe slots.
- Each service module controls eight PCIe slots.
Slot # |
Physical |
Electrical |
1 |
x16 |
x16 |
2 |
x8 |
x8 |
3 |
x16 |
x16 |
4 |
x8 |
x8 |
5 |
x16 |
x16 |
6 |
x8 |
x8 |
7 |
x16 |
x16 |
8 |
x8 |
x8 |
9 |
x16 |
x16 |
10 |
x8 |
x8 |
11 |
x16 |
x16 |
12 |
x8 |
x8 |
13 |
x16 |
x16 |
14 |
x8 |
x8 |
15 |
x16 |
x16 |
16 |
x8 |
x8 |
|
Internal Mass Storage |
Disks |
- Up to eight rear-accessible 2.5-inch SAS-3 drives; hot-swappable
- 600GB or 800GB or 1.2TB 2.5-inch SAS-3 disk drives
- 6.4TB NVMe Drives, maximum of eight
|
Power
Supplies and Fans |
- Four redundant, hot-swappable back panel accessible power supplies; 3000W
- Eight 80mm hot-swappable, redundant fan modules at chassis front
|
Environment |
Power Consumption |
Online
power calculator |
Input Voltage |
200 - 240 VAC, 50-60Hz
|
Maximum Heat Output |
13475 BTU/hr |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F) up to 900 meters (2,953 ft)
Nonoperating: -40° C to 68° C (-40° F to 154°F)
Note: Maximum ambient operating temperature is derated by 1° C per every 300m (984 ft) elevation
beyond 900m (3000 ft), up to a maximum altitude of 3,000m (9842 ft) elevation.
|
Humidity |
Operating: 10% to 90% noncondensing, short term -5° C to 55° C (25° F to 113° F)
5% to 90% noncondensing, but not to exceed 0.024kg of water per kg of dry air (0.053
lbs warer/2.205 lbs dry air)
Nonoperating: Up to 93% noncondensing 35° C (95° F) maximum wet bulb |
Altitude |
Operating: Up to 3000m (9,840 ft) at 35° C (95° F)
Note: In China markets, regulations might limit installations to a maximum altitude of 2000m (6562 ft).
Nonoperating: 0 to 12,000m (39,370 ft) |
Acoustic Noise Emissions |
Maximum Condition: 8.1 Bels
Idle Condition: 5.8 Bels |
Vibration |
Operating: 0.15 G (z-axis)
0.10 G (x-, y-axes), 5-500Hz swept sine
Nonoperating: 0.5 G (z-axis)
0.25 G (x-, y-axes), 5-500Hz swept sine |
Shock |
Operating: 3 Gs, 11 ms half-sine
Nonoperating:
Roll Off: 1.25 inch roll-off free fall, front to back rolling directions.
Threshold: 13mm threshold height at 0.65 m/s impact velocity. |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA 60950-1, EN 60950-1, IEC 60950-1 (CB Scheme with all country differences) |
EMC |
Emissions: FCC 47 CFR Part 15, ICES-003, EN 55032, EN610000-3-11, EN61000-3-12 |
Emissions and Immunity |
EN55024 |
Certifications |
Safety Marks |
North America (NRTL), European Union (EU), International CB Scheme, HSE
Exemption (India), BSMI (Taiwan), RCM (Australia), MSIP (Korea), VCCI (Japan),
Morocco, Republic of Srpska, Vietnam |
European Union Directives |
2014/35/EU Low Voltage Directive, 2014/30/EU EMC Directive, 2011/65/EU RoHS Directive, 2012/19/EU WEEE Directive
|
Dimensions
and Weight |
Height |
21.9 cm (8.62 in.) 5U |
Width |
44.6 cm (23.62 in.) |
Depth |
85 cm (33.6 in.) |
Weight |
Maximum: 114 kg (250 lbs.) |
Rack
Mounting & Clearance |
Maintenance Space Requirements
|
- Above the rack clearance: 91.4 cm (36 in)
- Front Minimum Clearance: 123.2 cm (48.5 in)
- Rear Minimum Clearance: 91.4 cm (36 in)
|