Processor |
Number |
1 or 2 Processors (two processors required for maximum memory and I/O configurations) |
Architecture |
Type: Intel Xeon Processor Scalable Family of Processors |
CPUs |
10-Core 2.2GHz Xeon S-4114, 85W
24-Core 2.1GHz Xeon P-8160, 150W
|
Cache |
Level 1: 32 KB instruction and 32 KB data L1 cache per core
Level 2: 1 MB shared data and instruction L2 cache per core
Level 3: Up to 1.375 MB shared inclusive L3 cache per core
|
Main Memory |
Capacities |
- 24 DIMM Slots
- DIMM Size and Type: 16GB or 32GB DDR4-2666
Registered DIMMs
- Minimum Memory Capacity: 1 DIMM per installed CPU is the minimum requirement.
- Maximum Memory Capacity: 768GB using
32GB DIMMs x 24 Slots in a 2 CPU configuration
|
Standard I/O |
Network Management |
- One 10/100/1000BASE-T RJ-45 Oracle Integrated Lights Out Manager (ILOM)
service processor (SP) network management (NET MGT) port.
- One 10/100/1000BASE-T RJ-45 Gigabit Ethernet (GbE) port, labeled NET 0
|
Serial Management |
One RJ-45 serial management (SER MGT) port |
USB |
Rear: 1 USB 3.0 Port
Internal: 1 USB 3.0 Port |
I/O Expansion |
Eleven PCIe 3.0 slots:
- Slots 1 and 7: x16 electrical interface
- Slots 1 through 6, and slots 8 through 11: x8 electrical interface
|
Internal
Mass Storage |
Disks |
- Up to twelve 10TB 7200 RPM, 3.5-inch hot-pluggable SAS3 HDDs
- Two hot-pluggable internal SATA/PCIe M.2 flash modules
|
Power Supplies and Fans |
Power Supplies |
Two hot-swappable and redundant power supplies, rated 91% efficiency.
|
Cooling Fans |
Four 80-mm, hot-swappable fan modules for chassis cooling. Each fan module contains one pair of counter-rotating fans.
Each power supply has its own cooling fans.
|
Environment |
Power Consumption |
Online power calculator |
AC power |
Rated line voltage: 100 to 240 VAC
Rated input current 100 to 127 VAC 8.5 A and 200 to 240 VAC 5.7 A
|
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 68° C (-40° F to 154°F) |
Relative Humidity |
Operating:
10% to 90% noncondensing, short term -5° C to 55° C (23° F to 113° F)
5% to 90% noncondensing, but not to exceed 0.024 kg of water per kg of dry air (0.053 lbs water/2.205 lbs dry air)
Nonoperating: Up to 93% noncondensing 35° C (95°F) maximum wet bulb |
Altitude |
Single, non-rack system:
Operating: Up to 3,000 m * (9,840 ft) maximum ambient temperature
is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft)
* In China markets, regulations may limit installations to a maximum altitude of 2,000 meters (6,562 feet)
Nonoperating: Up to 12,000 m (39,370 ft) |
Acoustic Noise |
Maximum condition: 7.1 Bels A-weighted operating
Idle condition: 7.0 Bels A weighted |
Vibration |
Operating: 0.15 G (z-axis)
0.10 G (x-, y-axes), 5-500Hz swept sine
IEC 60068-2-6 Test FC
Nonoperating:0.5 G (z-axis)
0.25 G (x-, y-axes), 5-500Hz swept sine
IEC 60068-2-6 Test FC |
Shock |
Operating: 3.5 G, 11 ms half-sine
IEC 60068-2-27 Test Ea
Nonoperating: Roll-off: 1.25-inch roll-off free fall, front to back rolling directions
Threshold: 13-mm threshold height at 0.65 m/s impact velocity
ETE-1010-02 Rev A |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA-60950-1, EN60950-1-2006, IEC60950-1 CB scheme with all country differences
|
EMC |
Emissions: FCC CFR 47 Part 15, ICES-003, EN55022, EN61000-3-2 and EN61000-3-3
|
Immunity |
EM55024
|
Other |
Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Waste Electrical and Electronic Equipment (WEEE) Directive 2012/19/EU, Low Voltage Directive 2006/95/EC, and EMC Directive 2004/108/EC
|
Certifications |
- North America Safety (NRTL)
- European Union (EU)
- International CB Scheme
- BIS (India)
- BSMI (Taiwan)
- RCM (Australia)
- CCC (PRC)
- MSIP (Korea)
- VCCI (Japan)
- Morocco
- Republic of Srpska
|
European Union Directives |
2014/35/EU Low Voltage Directive
- 2014/30 EMC Directive
- 2011/65/EU RoHS Directive
- 2012/19/EU WEEE Directive
|
Dimensions and Weight |
Height |
8.69 cm (3.42 in.). |
Width |
48.2cmm (18.9 in.). |
Depth |
75.9 cm (29.9 in.). |
Weight |
Fully Populated Server: 29.03kg (64lbs)
|
Rack
Mounting |
Oracle Server X7-2L Rack Installation Kits
|
- Tooless rackmounting slide rail kit
- Cable management arm
|